MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tmi.2006.882124

Медицинская библиотека · IEEE transactions on medical imaging · 2006

Automatic contour propagation in cine cardiac magnetic resonance images.

Hautvast Gilion, Lobregt Steven, Breeuwer Marcel, Gerritsen Frans

Оценочное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

We have developed a method for automatic contour propagation in cine cardiac magnetic resonance images. The method consists of a new active contour model that tries to maintain a constant contour environment by matching gray values in profiles perpendicular to the contour. Consequently, the contours should maintain a constant position with respect to neighboring anatomical structures, such that the resulting contours reflect the preferences of the user. This is particularly important in cine cardiac magnetic resonance images because local image features do not describe the desired contours near the papillary muscle. The accuracy of the propagation result is influenced by several parameters. Because the optimal setting of these parameters is application dependent, we describe how to use full factorial experiments to optimize the parameter setting. We have applied our method to cine cardiac magnetic resonance image sequences from the long axis two-chamber view, the long axis four-chamber view, and the short axis view. We performed our optimization procedure for each contour in each view. Next, we performed an extensive clinical validation of our method on 69 short axis data sets and 38 long axis data sets. In the optimal parameter setting, our propagation method proved to be fast, robust, and accurate. The resulting cardiac contours are positioned within the interobserver ranges of manual segmentation. Consequently, the resulting contours can be used to accurately determine physiological parameters such as stroke volume and ejection fraction.

Для цитирования: Hautvast Gilion, Lobregt Steven, Breeuwer Marcel, Gerritsen Frans. Automatic contour propagation in cine cardiac magnetic resonance images.. IEEE transactions on medical imaging. 2006. DOI: 10.1109/tmi.2006.882124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.