m+Medelevator.RU
← Поиск публикаций
American journal of physiology. Heart and circulatory physiology · 2004

Virtual electrode theory explains pacing threshold increase caused by cardiac tissue damage.

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sambelashvili Aleksandre T, Nikolski Vladimir P, Efimov Igor R

Аннотация

The virtual electrode polarization (VEP) effect is believed to play a key role in electrical stimulation of heart muscle. However, under certain conditions, including clinically, its existence and importance remain unknown. We investigated the influence of acute tissue damage produced by continuous pacing with strong current (40-mA, 4-ms biphasic pulses with 4-Hz frequency for 5 min) on stimulus-generated VEPs and pacing thresholds. A fluorescent optical mapping technique was used to obtain stimulus-induced transmembrane potential distribution around a pacing electrode applied to the ventricular surface of a Langendorff-perfused rabbit heart (n = 5). Maps and pacing thresholds were recorded before and after tissue damage. Spatial extents of electroporation and cell uncoupling were assessed by propidium iodide (n = 2) and connexin43 (n = 3) antibody staining, respectively. On the basis of these data, passive and active three-dimensional bidomain models were built to determine VEP patterns and thresholds for different-sized areas of the damaged region. Electrophysiological results showed that acute tissue damage led to disappearance of the VEP with an associated significant increase in pacing thresholds. Damage was expressed in electroporation and cell uncoupling within an approximately 1.0-mm-diameter area around the tip of the electrode. According to computer simulations, cell uncoupling, rather than electroporation, might be the direct cause of VEP elimination and threshold increase, which was nonlinearly dependent on the size of the damaged region. Fiber rotation with depth did not substantially affect the numerical results. The study explains failure to stimulate damaged tissue within the concepts of the VEP theory.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты