MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2319/071516-552.1

Медицинская библиотека · The Angle orthodontist · 2016

In vitro and in vivo evaluation of diamond-coated strips.

Lione Roberta, Gazzani Francesca, Pavoni Chiara, Guarino Stefano, Tagliaferri Vincenzo, Cozza Paola

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To test in vitro and in vivo the wear performance of diamond-coated strips by means of tribological testing and scanning electronic microscope (SEM).

MATERIALS AND

METHODS

To evaluate the in vitro wear performance, a tribological test was performed by a standard tribometer. The abrasive strips slid against stationary, freshly extracted premolars fixed in resin blocks, at a 2-newton load. At the end of the tribological test, the residual surface of the strip was observed by means of SEM analysis, which was performed every 50 meters until reaching 300 meters. For the in vivo analysis, the strip was used for 300 seconds, corresponding to 250 meters.

RESULTS

The strips presented a fenestrated structure characterized by diamond granules alternating with voids. After the first 50 meters, it was possible to observe tooth material deposited on the surface of the strips and a certain number of abrasive grains detached. The surface of the strip after 250 meters appeared smoother and therefore less effective in its abrasive power. After 300 seconds of in vivo utilization of the strip, it was possible to observe the detachment of diamond abrasive grains, the near absence of the grains and, therefore, loss of abrasive power.

CONCLUSIONS

Under ideal conditions, after 5 minutes (30 meters) of use, the strip loses its abrasive capacity by about 60%. In vivo, a more rapid loss of abrasive power was observed due to the greater load applied by the clinician in forcing the strip into the contact point.

Для цитирования: Lione Roberta, Gazzani Francesca, Pavoni Chiara, Guarino Stefano, Tagliaferri Vincenzo, Cozza Paola. In vitro and in vivo evaluation of diamond-coated strips.. The Angle orthodontist. 2016. DOI: 10.2319/071516-552.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.