Artificial neural network techniques to improve the ability of optical coherence tomography to detect optic neuritis.

Garcia-Martin Elena, Herrero Raquel, Bambo Maria P, Ara Jose R, Martin Jesus, Polo Vicente, Larrosa Jose M, Garcia-Feijoo Julian, Pablo Luis E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the ability of Spectralis optical coherence tomography (OCT) to detect multiple sclerosis (MS) and to distinguish MS eyes with antecedent optic neuritis (ON). To analyze the capability of artificial neural network (ANN) techniques to improve the diagnostic precision.

METHODS

MS patients and controls were enrolled (n = 217). OCT was used to determine the 768 retinal nerve fiber layer thicknesses. Sensitivity and specificity were evaluated to test the ability of OCT to discriminate between MS and healthy eyes, and between MS with and without antecedent ON using ANN.

RESULTS

Using ANN technique multilayer perceptrons, OCT could detect MS with a sensitivity of 89.3%, a specificity of 87.6%, and a diagnostic precision of 88.5%. Compared with the OCT-provided parameters, the ANN had a better sensitivity-specificity balance.

CONCLUSIONS

ANN technique improves the capability of Spectralis OCT to detect MS disease and to distinguish MS eyes with or without antecedent ON.

Для цитирования: Garcia-Martin Elena, Herrero Raquel, Bambo Maria P, Ara Jose R, Martin Jesus, Polo Vicente, Larrosa Jose M, Garcia-Feijoo Julian, Pablo Luis E. Artificial neural network techniques to improve the ability of optical coherence tomography to detect optic neuritis.. Seminars in ophthalmology. 2013. DOI: 10.3109/08820538.2013.810277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.