MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000350413

Медицинская библиотека · Ophthalmic research · 2013

Three-dimensional geometries representing the retinal nerve fiber layer in multiple sclerosis, optic neuritis, and healthy eyes.

Garcia-Martin E, Calvo B, Malvè M, Herrero R, Fuertes I, Ferreras A, Larrosa J M, Polo V, Pablo L E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To represent and interpret the three-dimensional (3D) geometry and the distribution of the axonal damage to the retinal nerve fiber layer (RNFL) in patients with multiple sclerosis (MS) compared with healthy subjects. To analyze alterations in RNFL morphology in eyes of MS patients with or without previous episodes of optic neuritis (ON).

METHODS

MS patients (n = 122) and age-matched healthy subjects (n = 108) were enrolled. The Spectralis optical coherence tomography system was used to determine the circumpapillary RNFL thickness. The 768 RNFL thickness measurements were used to evaluate thickness measurements in patients with or without antecedent ON and to design a 3D reconstruction of the RNFL thickness representing the mechanobiologic tissue response to neurodegeneration caused by MS and ON episodes.

RESULTS

RNFL thickness was decreased in MS patients, and was higher in the MS group with previous ON. Statistical analysis and 3D RNFL reconstruction revealed greater damage to the ganglionar cells in the superonasal RNFL area (101.77 µm in MS vs. 125.47 µm in healthy subjects) and in the inferotemporal RNFL (119.05 µm in MS eyes and 149.26 µm in healthy eyes).

CONCLUSIONS

The 3D representation of RNFL thickness based on measurements allows physicians to better observe damage in the temporal areas, especially in patients with previous ON.

Для цитирования: Garcia-Martin E, Calvo B, Malvè M, Herrero R, Fuertes I, Ferreras A, Larrosa J M, Polo V, Pablo L E. Three-dimensional geometries representing the retinal nerve fiber layer in multiple sclerosis, optic neuritis, and healthy eyes.. Ophthalmic research. 2013. DOI: 10.1159/000350413.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.