Ultrasound-guided modified dynamic needle tip positioning technique for distal radial artery catheterization: A randomized controlled trial.

Liang Yupeng, Liu Peizhong, Wei Chao, Li Wenjin, Li Chuangpeng, Lai Tianwei, Peng Se, Xu Jiamin, Zhang Hezhen, Li Pusheng, Li Shaohui

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The distal radial artery presents a particular challenge for puncture and catheterization due to its diminutive size, tortuous path, and tendency to spasm, increasing the risk of procedural failure and injury. Ultrasound guidance improves success rates and reduces risk in radial artery catheterization. This study evaluates the efficacy and safety of a refined dynamic needle tip positioning technique for distal radial artery access.

METHODS

One hundred twelve patients were randomized to either the modified dynamic needle tip positioning technique (MDNTP) or palpation guidance groups (palpation group), each with 56 participants. The primary outcomes were the success rate of the initial puncture and overall puncture success rate, while secondary outcomes included procedural time and complications such as puncture site hematoma and radial artery occlusion within 24 h.

RESULTS

The MDNTP group exhibited superior initial puncture success (71.43% vs 46.43%, p < 0.05) and fewer puncture attempts (median 1 (1, 2) vs 2 (1, 4), p < 0.05), resulting in a higher overall puncture success rate (98.21% vs 87.50%, p = 0.028). Notably, sheath insertion times were significantly shorter (17 (12, 21) s vs 57 (32, 100) s, p = 0.001) and the Sheath insertion success rate was higher (96.43% vs 82.14%, p = 0.015) in the MDNTP group. Furthermore, the incidence of puncture site hematomas was reduced (5.36% vs 19.64%, p = 0.022), although puncture time was longer (60 (28, 116) s vs 40 (15, 79) s, p = 0.033). Despite these differences, total procedural time and the incidence of radial artery occlusion at 24 h postoperatively were comparable between the two groups.

CONCLUSION

The MDNTP technique boosts the success of distal radial artery puncture and catheterization, reducing the risk of complications associated with the procedure.

Для цитирования: Liang Yupeng, Liu Peizhong, Wei Chao, Li Wenjin, Li Chuangpeng, Lai Tianwei, Peng Se, Xu Jiamin, Zhang Hezhen, Li Pusheng, Li Shaohui. Ultrasound-guided modified dynamic needle tip positioning technique for distal radial artery catheterization: A randomized controlled trial.. The journal of vascular access. 2024. DOI: 10.1177/11297298241270537.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.