Merkely Béla, Hatala Robert, Merkel Eperke, Szigeti Mátyás, Veres Boglárka, Fábián Alexandra, Osztheimer István, Gellér László, Sasov Michal, Wranicz Jerzy K, Földesi Csaba, Duray Gábor, Solomon Scott D, Kutyifa Valentina, Kovács Attila, Kosztin Annamária
Аннотация
AIMS: Recommendations on cardiac resynchronization therapy (CRT) in patients with atrial fibrillation or flutter (AF) are based on less robust evidence than those in sinus rhythm (SR). We aimed to assess the efficacy of CRT upgrade in the BUDAPEST-CRT Upgrade trial population by their baseline rhythm.
METHODS AND RESULTS: Heart failure patients with reduced ejection fraction (HFrEF) and previously implanted pacemaker (PM) or implantable cardioverter defibrillator (ICD) and ≥20% right ventricular (RV) pacing burden were randomized to CRT with defibrillator (CRT-D) upgrade (n = 215) or ICD (n = 145). Primary [HF hospitalization (HFH), all-cause mortality, or <15% reduction of left ventricular end-systolic volume] and secondary outcomes were investigated. At enrolment, 131 (36%) patients had AF, who had an increased risk for HFH as compared with those with SR [adjusted hazard ratio (aHR) 2.99; 95% confidence interval (CI) 1.26-7.13; P = 0.013]. The effect of CRT-D upgrade was similar in patients with AF as in those with SR [AF adjusted odds ratio (aOR) 0.06; 95% CI 0.02-0.17; P < 0.001; SR aOR 0.13; 95% CI 0.07-0.27; P < 0.001; interaction P = 0.29] during the mean follow-up time of 12.4 months. Also, it decreased the risk of HFH or all-cause mortality (aHR 0.33; 95% CI 0.16-0.70; P = 0.003; interaction P = 0.17) and improved the echocardiographic response (left ventricular end-diastolic volume difference -49.21 mL; 95% CI -69.10 to -29.32; P < 0.001; interaction P = 0.21).
CONCLUSION: In HFrEF patients with AF and PM/ICD with high RV pacing burden, CRT-D upgrade decreased the risk of HFH and improved reverse remodelling when compared with ICD, similar to that seen in patients in SR.
METHODS AND RESULTS: Heart failure patients with reduced ejection fraction (HFrEF) and previously implanted pacemaker (PM) or implantable cardioverter defibrillator (ICD) and ≥20% right ventricular (RV) pacing burden were randomized to CRT with defibrillator (CRT-D) upgrade (n = 215) or ICD (n = 145). Primary [HF hospitalization (HFH), all-cause mortality, or <15% reduction of left ventricular end-systolic volume] and secondary outcomes were investigated. At enrolment, 131 (36%) patients had AF, who had an increased risk for HFH as compared with those with SR [adjusted hazard ratio (aHR) 2.99; 95% confidence interval (CI) 1.26-7.13; P = 0.013]. The effect of CRT-D upgrade was similar in patients with AF as in those with SR [AF adjusted odds ratio (aOR) 0.06; 95% CI 0.02-0.17; P < 0.001; SR aOR 0.13; 95% CI 0.07-0.27; P < 0.001; interaction P = 0.29] during the mean follow-up time of 12.4 months. Also, it decreased the risk of HFH or all-cause mortality (aHR 0.33; 95% CI 0.16-0.70; P = 0.003; interaction P = 0.17) and improved the echocardiographic response (left ventricular end-diastolic volume difference -49.21 mL; 95% CI -69.10 to -29.32; P < 0.001; interaction P = 0.21).
CONCLUSION: In HFrEF patients with AF and PM/ICD with high RV pacing burden, CRT-D upgrade decreased the risk of HFH and improved reverse remodelling when compared with ICD, similar to that seen in patients in SR.
Предметные рубрики MeSH
HumansAtrial FibrillationMaleFemaleCardiac Resynchronization TherapyAgedHeart FailureStroke VolumeTreatment OutcomeMiddle AgedDefibrillators, ImplantableVentricular Function, RightVentricular Function, LeftCardiac Resynchronization Therapy DevicesRisk FactorsHospitalizationElectric CountershockTime FactorsAged, 80 and over