Variation in optimal hemodynamic atrio-ventricular delay of biventricular pacing with different endocardial left ventricular lead locations using precision hemodynamics.

Butcher Charles J T, Cantor Emily, Sohaib Afzal, Shun-Shin Matthew J, Haynes Ross, Khan Habib, Kyriacou Adreas, Shi Rui, Chen Zhong, Haldar Shouvik, Cleland John G F, Hussain Wajid, Markides Vias, Jones David G, Lane Rebecca E, Mason Mark J, Whinnett Zachary I, Francis Darrel P, Wong Tom

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration.

METHODS

We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms.

RESULTS

Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg).

CONCLUSION

Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.

Для цитирования: Butcher Charles J T, Cantor Emily, Sohaib Afzal, Shun-Shin Matthew J, Haynes Ross, Khan Habib, Kyriacou Adreas, Shi Rui, Chen Zhong, Haldar Shouvik, Cleland John G F, Hussain Wajid, Markides Vias, Jones David G, Lane Rebecca E, Mason Mark J, Whinnett Zachary I, Francis Darrel P, Wong Tom. Variation in optimal hemodynamic atrio-ventricular delay of biventricular pacing with different endocardial left ventricular lead locations using precision hemodynamics.. Journal of cardiovascular electrophysiology. 2023. DOI: 10.1111/jce.15862.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.