The Journal of thoracic and cardiovascular surgery · 2024
Five-year outcomes of transcarotid transcatheter aortic valve replacement.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Del Portillo Juan Hernando, Kalavrouziotis Dimitri, Dumont Eric, Paradis Jean-Michel, Poulin Anthony, Beaupré Frederic, Avvedimento Marisa, Mas-Peiro Silvia, Cepas-Guillén Pedro, Mengi Siddhartha, Mohammadi Siamak, Rodés-Cabau Josep
Аннотация
BACKGROUND: Transcarotid transcatheter aortic valve replacement (TC-TAVR) has emerged as an alternative access route for transcatheter aortic valve replacement (TAVR). However, scarce data exist on long-term outcomes following TC-TAVR. This study aimed to evaluate clinical outcomes at 5 years after TC-TAVR.
METHODS: A total of 110 consecutive patients who underwent TC-TAVR were included. Baseline, procedural, and follow-up data were collected prospectively in a dedicated database. The primary endpoint was the incidence of a composite outcome of all-cause mortality, stroke, and repeat hospitalization at 5-year follow-up. Echocardiography results, New York Heart Association (NYHA) class, and quality of life (QoL) as assessed with the EuroQol visual analog scale (EQ-VAS) were examined over the 5-year follow-up.
RESULTS: The median patient age was 77 years (interquartile range [IQR], 72-82.2 years), 42.3% were women, and the median Society of Thoracic Surgeons (STS) risk score was 5.02% (IQR, 3.4%-7.5%). The incidence of the composite primary endpoint was 54.5%. Death from any cause occurred in 45.6% of patients (11.9 per 100 patient-years); stroke in 8.2% (1.9 per 100 patient-years); disabling stroke in 2.7% (0.7 per 100 patient-years); and rehospitalization in 27.2%. The improvements in valve hemodynamics, NYHA class, and EQ-VAS following the procedure persisted at 5-year follow-up (P < .001). The incidence of bioprosthetic valve failure was 0.9%.
CONCLUSIONS: About half of the moderate-to high-risk patients undergoing TC-TAVR survived with no major cardiovascular events at the 5-year follow-up. The yearly incidence of stroke events was low, and early improvements in valve hemodynamics, functional status, and QoL persisted at 5 years. These results suggest the long-term safety and efficacy of TC-TAVR and would support this approach as an alternative to surgery in non-transfemoral candidates.
METHODS: A total of 110 consecutive patients who underwent TC-TAVR were included. Baseline, procedural, and follow-up data were collected prospectively in a dedicated database. The primary endpoint was the incidence of a composite outcome of all-cause mortality, stroke, and repeat hospitalization at 5-year follow-up. Echocardiography results, New York Heart Association (NYHA) class, and quality of life (QoL) as assessed with the EuroQol visual analog scale (EQ-VAS) were examined over the 5-year follow-up.
RESULTS: The median patient age was 77 years (interquartile range [IQR], 72-82.2 years), 42.3% were women, and the median Society of Thoracic Surgeons (STS) risk score was 5.02% (IQR, 3.4%-7.5%). The incidence of the composite primary endpoint was 54.5%. Death from any cause occurred in 45.6% of patients (11.9 per 100 patient-years); stroke in 8.2% (1.9 per 100 patient-years); disabling stroke in 2.7% (0.7 per 100 patient-years); and rehospitalization in 27.2%. The improvements in valve hemodynamics, NYHA class, and EQ-VAS following the procedure persisted at 5-year follow-up (P < .001). The incidence of bioprosthetic valve failure was 0.9%.
CONCLUSIONS: About half of the moderate-to high-risk patients undergoing TC-TAVR survived with no major cardiovascular events at the 5-year follow-up. The yearly incidence of stroke events was low, and early improvements in valve hemodynamics, functional status, and QoL persisted at 5 years. These results suggest the long-term safety and efficacy of TC-TAVR and would support this approach as an alternative to surgery in non-transfemoral candidates.