DOI 10.1159/000538905

Медицинская библиотека · Neonatology · 2024

Real-Time Ultrasound Tip Location Reduces Malposition and Radiation Exposure during Umbilical Venous Catheter Placement in Neonates: A Retrospective, Observational Study.

D'Andrea Vito, Prontera Giorgia, Cota Francesco, Perri Alessandro, Russo Rosellina, Barone Giovanni, Vento Giovanni

СтатьяНаблюдательное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The umbilical venous catheter is a vital access device in neonatal intensive care units for preterm and critically ill infants. Correct positioning is crucial, as malpositioning can lead to severe complications. According to international guidelines, the position of the umbilical venous catheter tip must be assessed in real time; traditionally, the catheter is visualized with a thoracoabdominal X-ray, but one of the most effective and safest methods is therefore real-time ultrasound.

METHODS

This study compares real-time ultrasound and traditional X-ray methods for assessing umbilical venous catheter tip location in 461 cases. The rate of tip malposition was analyzed retrospectively. The secondary aim was to assess indwelling time of umbilical venous catheters and reasons of removal.

RESULTS

Real-time ultrasound tip location, found to be more reliable and efficient, demonstrated a significantly lower incidence of primary malpositioning compared to X-ray assessments (9.6 vs. 75.9%). The study also highlighted the association of real-time ultrasound with reduced catheter manipulation, fewer radiographs, and higher indwelling times of umbilical venous catheter. The multiple logistic regression showed a high probability of the central safe position of the umbilical venous catheter tip using real-time ultrasound tip location (odds ratio 29.5, 95% confidence interval: 17.4-49.4).

CONCLUSION

The findings support the adoption of real-time ultrasound in clinical settings to enhance umbilical venous catheter placement accuracy and minimize associated risks. A minimal training investment is needed to attain the proficiency to visualize the umbilical venous catheters, offering a substantial advantage in terms of both cost-effectiveness for the procedure and enhanced patient safety.

Для цитирования: D'Andrea Vito, Prontera Giorgia, Cota Francesco, Perri Alessandro, Russo Rosellina, Barone Giovanni, Vento Giovanni. Real-Time Ultrasound Tip Location Reduces Malposition and Radiation Exposure during Umbilical Venous Catheter Placement in Neonates: A Retrospective, Observational Study.. Neonatology. 2024. DOI: 10.1159/000538905.