MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hroo.2022.10.002

Медицинская библиотека · Heart rhythm O2 · 2022

On-screen image-guided lead placement in cardiac resynchronization therapy: Feasibility and outcome in a multicenter setting.

Wouters Philippe C, van Slochteren Frebus J, Tuinenburg Anton E, Doevendans Pieter A, Cramer Maarten-Jan M, Delnoy Peter-Paul H M, van Dijk Vincent F, Meine Mathias

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Image guidance to assist left ventricular (LV) lead placement may improve outcome after cardiac resynchronization therapy (CRT), but previous approaches and results varied greatly, and multicenter feasibility is lacking altogether.

OBJECTIVE

We sought to investigate the multicenter feasibility of image guidance for periprocedural assistance of LV lead placement for CRT.

METHODS

In 30 patients from 3 hospitals, cardiac magnetic resonance imaging was performed within 3 months prior to CRT to identify myocardial scar and late mechanical activation (LMA). LMA was determined using radial strain, plotted over time. Segments without scar but clear LMA were classified as optimal for LV lead placement, according to an accurate 36-segment model of the whole heart. LV leads were navigated using image overlay with periprocedural fluoroscopy. After 6 months, volumetric response and super-response were defined as ≥15% or ≥30% reduction in LV end-systolic volume, respectively.

RESULTS

Periprocedural image guidance was successfully performed in all CRT patients (age 66 ± 10 years; 59% men, 62% with nonischemic cardiomyopathy, 69% with left bundle branch block). LV leads were placed as follows: within (14%), adjacent (62%), or remote (24%) from the predefined target. According to the conventional 18-segment model, a remote position occurred only once (3%). On average, 86% of patients demonstrated a volumetric response (mean LV end-systolic volume reduction 36 ± 29%), and 66% of all patients were super-responders.

CONCLUSION

On-screen image guidance for LV lead placement in CRT was feasible in a multicenter setting. Efficacy will be further investigated in the randomized controlled ADVISE (Advanced Image Supported Lead Placement in Cardiac Resynchronization Therapy) trial (NCT05053568).

Для цитирования: Wouters Philippe C, van Slochteren Frebus J, Tuinenburg Anton E, Doevendans Pieter A, Cramer Maarten-Jan M, Delnoy Peter-Paul H M, van Dijk Vincent F, Meine Mathias. On-screen image-guided lead placement in cardiac resynchronization therapy: Feasibility and outcome in a multicenter setting.. Heart rhythm O2. 2022. DOI: 10.1016/j.hroo.2022.10.002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.