Elliott Mark K, Strocchi Marina, Sieniewicz Benjamin J, Sidhu Baldeep, Mehta Vishal, Wijesuriya Nadeev, Behar Jonathan M, Thorpe Andrew, Martic Dejana, Wong Tom, Niederer Steven, Rinaldi Christopher A
Аннотация
BACKGROUND: Biventricular endocardial pacing (BiV-endo) has demonstrated superior cardiac resynchronization compared to conventional biventricular epicardial pacing (BiV-epi). Left bundle branch area pacing (LBBAP) may also achieve effective cardiac resynchronization therapy (CRT).
OBJECTIVE: The purpose of this study was to compare the acute electrical and hemodynamic effects of BiV-epi, BiV-endo, and LBBAP delivered from the LV endocardium and to assess how myocardial scar affects response.
METHODS: Eleven patients with heart failure and indications for CRT underwent a temporary pacing study with electrocardiographic imaging (ECGi) and hemodynamic assessment. BiV-endo was delivered by stimulation of the left ventricular (LV) lateral wall, and LBBAP was delivered by stimulation of the LV septum, at the site of a Purkinje potential. LV activation time (LVAT-95), LV dyssynchrony index (LVDI), biventricular activation time (BIVAT-90), and biventricular dyssynchrony index (BIVDI) were calculated. Myocardial scar was assessed using magnetic resonance imaging (MRI).
RESULTS: The protocol was completed in 10 patients. Compared to BiV-epi (LVAT-95: 79.2 ± 13.1 ms; LVDI: 26.6 ± 3.4 ms) LV resynchronization was superior during BiV-endo (LVAT-95: 48.5 ± 14.9 ms; P = .001; LVDI: 16.6 ± 6.4 ms; P = .002) and LBBAP (LVAT-95: 48.9 ± 12.5 ms; P = .001; LVDI: 15.3 ± 3.4 ms; P = .001). Biventricular resynchronization was similarly superior during BiV-endo and LBBAP vs BiV-epi (BIVAT-90 and BIVDI; P <.05). The rate of acute hemodynamic responders was higher during BiV-endo (90%) and LBBAP (70%) vs BiV-epi (50%). The benefits of LBBAP (but not BiV-endo) on LV resynchronization were attenuated when septal scar was present in a subset of 8 patients who underwent MRI.
CONCLUSION: Our findings suggest superior electrical resynchronization and a higher proportion of acute hemodynamic responders during BiV-endo and LBBAP compared to BiV-epi. Electrical resynchronization was similar between BiV-endo and LBBAP; however, septal scar seemed to attenuate response to LBBAP.
OBJECTIVE: The purpose of this study was to compare the acute electrical and hemodynamic effects of BiV-epi, BiV-endo, and LBBAP delivered from the LV endocardium and to assess how myocardial scar affects response.
METHODS: Eleven patients with heart failure and indications for CRT underwent a temporary pacing study with electrocardiographic imaging (ECGi) and hemodynamic assessment. BiV-endo was delivered by stimulation of the left ventricular (LV) lateral wall, and LBBAP was delivered by stimulation of the LV septum, at the site of a Purkinje potential. LV activation time (LVAT-95), LV dyssynchrony index (LVDI), biventricular activation time (BIVAT-90), and biventricular dyssynchrony index (BIVDI) were calculated. Myocardial scar was assessed using magnetic resonance imaging (MRI).
RESULTS: The protocol was completed in 10 patients. Compared to BiV-epi (LVAT-95: 79.2 ± 13.1 ms; LVDI: 26.6 ± 3.4 ms) LV resynchronization was superior during BiV-endo (LVAT-95: 48.5 ± 14.9 ms; P = .001; LVDI: 16.6 ± 6.4 ms; P = .002) and LBBAP (LVAT-95: 48.9 ± 12.5 ms; P = .001; LVDI: 15.3 ± 3.4 ms; P = .001). Biventricular resynchronization was similarly superior during BiV-endo and LBBAP vs BiV-epi (BIVAT-90 and BIVDI; P <.05). The rate of acute hemodynamic responders was higher during BiV-endo (90%) and LBBAP (70%) vs BiV-epi (50%). The benefits of LBBAP (but not BiV-endo) on LV resynchronization were attenuated when septal scar was present in a subset of 8 patients who underwent MRI.
CONCLUSION: Our findings suggest superior electrical resynchronization and a higher proportion of acute hemodynamic responders during BiV-endo and LBBAP compared to BiV-epi. Electrical resynchronization was similar between BiV-endo and LBBAP; however, septal scar seemed to attenuate response to LBBAP.