Biventricular endocardial pacing and left bundle branch area pacing for cardiac resynchronization: Mechanistic insights from electrocardiographic imaging, acute hemodynamic response, and magnetic resonance imaging.

Elliott Mark K, Strocchi Marina, Sieniewicz Benjamin J, Sidhu Baldeep, Mehta Vishal, Wijesuriya Nadeev, Behar Jonathan M, Thorpe Andrew, Martic Dejana, Wong Tom, Niederer Steven, Rinaldi Christopher A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Biventricular endocardial pacing (BiV-endo) has demonstrated superior cardiac resynchronization compared to conventional biventricular epicardial pacing (BiV-epi). Left bundle branch area pacing (LBBAP) may also achieve effective cardiac resynchronization therapy (CRT).

OBJECTIVE

The purpose of this study was to compare the acute electrical and hemodynamic effects of BiV-epi, BiV-endo, and LBBAP delivered from the LV endocardium and to assess how myocardial scar affects response.

METHODS

Eleven patients with heart failure and indications for CRT underwent a temporary pacing study with electrocardiographic imaging (ECGi) and hemodynamic assessment. BiV-endo was delivered by stimulation of the left ventricular (LV) lateral wall, and LBBAP was delivered by stimulation of the LV septum, at the site of a Purkinje potential. LV activation time (LVAT-95), LV dyssynchrony index (LVDI), biventricular activation time (BIVAT-90), and biventricular dyssynchrony index (BIVDI) were calculated. Myocardial scar was assessed using magnetic resonance imaging (MRI).

RESULTS

The protocol was completed in 10 patients. Compared to BiV-epi (LVAT-95: 79.2 ± 13.1 ms; LVDI: 26.6 ± 3.4 ms) LV resynchronization was superior during BiV-endo (LVAT-95: 48.5 ± 14.9 ms; P = .001; LVDI: 16.6 ± 6.4 ms; P = .002) and LBBAP (LVAT-95: 48.9 ± 12.5 ms; P = .001; LVDI: 15.3 ± 3.4 ms; P = .001). Biventricular resynchronization was similarly superior during BiV-endo and LBBAP vs BiV-epi (BIVAT-90 and BIVDI; P <.05). The rate of acute hemodynamic responders was higher during BiV-endo (90%) and LBBAP (70%) vs BiV-epi (50%). The benefits of LBBAP (but not BiV-endo) on LV resynchronization were attenuated when septal scar was present in a subset of 8 patients who underwent MRI.

CONCLUSION

Our findings suggest superior electrical resynchronization and a higher proportion of acute hemodynamic responders during BiV-endo and LBBAP compared to BiV-epi. Electrical resynchronization was similar between BiV-endo and LBBAP; however, septal scar seemed to attenuate response to LBBAP.

Для цитирования: Elliott Mark K, Strocchi Marina, Sieniewicz Benjamin J, Sidhu Baldeep, Mehta Vishal, Wijesuriya Nadeev, Behar Jonathan M, Thorpe Andrew, Martic Dejana, Wong Tom, Niederer Steven, Rinaldi Christopher A. Biventricular endocardial pacing and left bundle branch area pacing for cardiac resynchronization: Mechanistic insights from electrocardiographic imaging, acute hemodynamic response, and magnetic resonance imaging.. Heart rhythm. 2022. DOI: 10.1016/j.hrthm.2022.10.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.