MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1044/1059-0889(2013/13-0005)

Медицинская библиотека · American journal of audiology · 2013

Tinnitus and normal hearing: a study on contralateral acoustic reflex.

Fernandes Luciene da Cruz, Momensohn-Santos Teresa Maria, Carvalho Josiane Silva Martins, Carvalho Fernando Luís de Queiroz

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to evaluate the difference of the contralateral acoustic reflex (AR) threshold between adult subjects with hearing within clinically normal limits, with and without tinnitus.

METHOD: The study sample in this exploratory, descriptive, and comparative study comprised 40 female subjects who were evaluated: 20 had tinnitus and 20 formed the control group. The contralateral AR threshold was evaluated at the frequencies of 500, 1000, and 2000 Hz.

RESULTS

Elevated or absent AR thresholds were found only in subjects with complaints of tinnitus. At all frequencies and in either ear, the median AR threshold was higher in the group that complained of tinnitus (100.0 dB; range = 95.0–100.0 dB) compared with the control group (90.0 dB; range = 86.3–95.0 dB; p < .01). There was a statistically significant difference ( p < .05) in the group with tinnitus, in each of the frequencies studied and in both the right and left ear.

CONCLUSION

The results suggest that evaluation of the efferent system, through AR, could be an important tool for the differential diagnosis of tinnitus in patients whose hearing was within clinically normal limits.

Для цитирования: Fernandes Luciene da Cruz, Momensohn-Santos Teresa Maria, Carvalho Josiane Silva Martins, Carvalho Fernando Luís de Queiroz. Tinnitus and normal hearing: a study on contralateral acoustic reflex.. American journal of audiology. 2013. DOI: 10.1044/1059-0889(2013/13-0005).

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.