MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.yrtph.2012.12.006

Медицинская библиотека · Regulatory toxicology and pharmacology : RTP · 2012

Performance standards and alternative assays: practical insights from skin sensitization.

Kolle Susanne N, Basketter David A, Casati Silvia, Stokes William S, Strickland Judy, van Ravenzwaay Bennard, Vohr Hans-Werner, Landsiedel Robert

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

To encourage the development and validation of alternative toxicity test methods, the effort required for validation of test methods proposed for regulatory purposes should be minimized. Performance standards (PS) facilitate efficient validation by requiring limited testing. Based on the validated method, PS define accuracy and reliability values that must be met by the new similar test method. The OECD adopted internationally harmonized PS for evaluating new endpoint versions of the local lymph node assay (LLNA). However, in the process of evaluating a lymph node cell count alternative (LNCC), simultaneous conduct of the regulatory LLNA showed that this standard test may not always perform in perfect accord with its own PS. The LNCC results were similar to the concurrent LLNA. Discrepancies between PS, LLNA and LNCC were largely associated with "borderline" substances and the variability of both endpoints. Two key lessons were learned: firstly, the understandable focus on substances close to the hazard classification borderline are more likely to emphasise issues of biological variability, which should be taken into account during the evaluation of results; secondly, variability in the results for the standard assay should be considered when selecting reference chemicals for PS.

Для цитирования: Kolle Susanne N, Basketter David A, Casati Silvia, Stokes William S, Strickland Judy, van Ravenzwaay Bennard, Vohr Hans-Werner, Landsiedel Robert. Performance standards and alternative assays: practical insights from skin sensitization.. Regulatory toxicology and pharmacology : RTP. 2012. DOI: 10.1016/j.yrtph.2012.12.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.