MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diagmicrobio.2019.05.012

Медицинская библиотека · Diagnostic microbiology and infectious disease · 2019

Collaborative national multicenter for the identification of conversion factors from copies/mL to international units/mL for the normalization of HCMV DNA load.

Sidoti Francesca, Piralla Antonio, Costa Cristina, Scarasciulli Maria Luisa, Calvario Agata, Conaldi Pier Giulio, Paba Pierpaolo, Perno Carlo Federico, Gaeta Aurelia, Antonelli Guido, Sodano Giuseppe, Santangelo Rosaria, Sanguinetti Maurizio, Vatteroni Maria Linda, Barzon Luisa, Palù Giorgio, Abbate Isabella, Capobianchi Maria Rosaria, Piccirilli Giulia, Lazzarotto Tiziana, Baldanti Fausto, Cavallo Rossana

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

The present multicentric (n = 11 laboratories) study aimed to identify conversion factors from copies/mL to international units (IU)/mL for the normalization of HCMV DNA load using the first WHO International Standard for HCMV nucleic acid amplification techniques and to enhance interlaboratory agreement of HCMV DNA quantification methods. Study protocols for whole blood and plasma (extraction and amplification) were performed to calculate conversion factors from HCMV DNA copy number to IU. The greatest variability was observed in samples with lower HCMV concentrations (3.0 Log10) in both biological matrices. Overall, 73.1% (206/282) of whole blood and 82.2% (324/394) of plasma samples analyzed fell within an acceptable variation range (±0.5 Log10 difference). An average of 0.64 (range 0.21-1.17) was the conversion factor calculated for the HCMV whole blood panel and 0.82 (range 0.39-2.2) for the HCMV plasma panel.

Для цитирования: Sidoti Francesca, Piralla Antonio, Costa Cristina, Scarasciulli Maria Luisa, Calvario Agata, Conaldi Pier Giulio, Paba Pierpaolo, Perno Carlo Federico, Gaeta Aurelia, Antonelli Guido, Sodano Giuseppe, Santangelo Rosaria, Sanguinetti Maurizio, Vatteroni Maria Linda, Barzon Luisa, Palù Giorgio, Abbate Isabella, Capobianchi Maria Rosaria, Piccirilli Giulia, Lazzarotto Tiziana, Baldanti Fausto, Cavallo Rossana. Collaborative national multicenter for the identification of conversion factors from copies/mL to international units/mL for the normalization of HCMV DNA load.. Diagnostic microbiology and infectious disease. 2019. DOI: 10.1016/j.diagmicrobio.2019.05.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.