MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s42155-026-00758-9

Медицинская библиотека · CVIR endovascular · 2026

Embolisation of simple PAVMs with high-volume detachable non-fibered coils: a 3-year follow-up study.

van den Heuvel Daniel A F, Sachumsky Douwe, Zijp Bette, Mager Johannes J, van Leersum Marc, Post Marco C, Klompmaker Sjors

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine pulmonary arteriovenous malformation (PAVM) persistence and safety of high-volume detachable non-fibred (HVDNF) coil embolisation of de novo simple PAVMs using computed tomography pulmonary angiography (CTPA) at 6-month and 3-year follow-up.

METHODS

This retrospective single-cohort study included patients who underwent embolisation of de novo simple PAVMs, exclusively with HVDNF coils, between January 2018 and January 2021. Primary endpoints were PAVM persistence at 6 months, cumulative persistence at 3 years and coil recanalisation at 6 months and 3 years. Secondary endpoints were technical success, safety, repeat embolisation and vein diameter reduction. Persistence and recanalisation were confirmed with digital subtraction angiography (DSA).

RESULTS

This study included 50 patients with 75 de novo PAVMs. PAVM persistence at 6 months was 13.2%; cumulative persistence at 3 years was 17.4%. Coil recanalisation was the persistence mechanism in 10.3% of the cases at 6 months; at 3 years, this was 13.0%. Technical success rate was 98.7%. There were no procedure- or PAVM-related serious adverse events. Repeat embolisation with HVDNF coils was performed in 4 PAVMs after 6 months and 5 PAVMs after 3 years. Mean vein diameter reduction was 38.3% (SD 29.4%) at 6 months and 44.6% (SD 36.5%) at 3 years.

CONCLUSIONS

HVDNF coils are safe to use for de novo PAVM embolisation, show an excellent technical success rate and are associated with acceptable 6-month and 3-year persistence and coil recanalisation rates.

Для цитирования: van den Heuvel Daniel A F, Sachumsky Douwe, Zijp Bette, Mager Johannes J, van Leersum Marc, Post Marco C, Klompmaker Sjors. Embolisation of simple PAVMs with high-volume detachable non-fibered coils: a 3-year follow-up study.. CVIR endovascular. 2026. DOI: 10.1186/s42155-026-00758-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.