Scientific reports · 2026
A hybrid AI vision model for single-camera tracking of rehabilitation exercises: a proof of concept in clinical settings.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Das Utpal Chandra, Le Ngoc Thien, Vitoonpong Timporn, Pongmala Chatkaew, Prapinpairoj Chalermdej, Anannub Kawee, Kaewplung Pasu, Chaitusaney Surachai, Benjapolakul Watit
Аннотация
Accurate measurement of range of motion (ROM) during physical rehabilitation is traditionally achieved using goniometers or multi-camera, marker-based motion capture systems. The latter, while highly accurate, require specialised laboratory infrastructure, are costly, and are unsuitable for home-based use. There is growing interest in markerless, camera-based alternatives that leverage artificial intelligence (AI) for joint angle estimation. This study presents a preliminary proof-of-concept evaluation of a hybrid AI vision system, combining the MediaPipe Pose framework (version 0.8.9.1, Full model variant) with a Mamdani-type fuzzy inference system, for joint angle estimation and exercise repetition counting using a single consumer-grade camera. Fourteen healthy adult rehabilitation staff members performed three exercises (elbow flexion, knee extension, and hip external rotation) simultaneously recorded by the proposed AI system and by a reference optical motion capture system (C-Motion Visual3D™, 14 calibrated infrared cameras, 53 retro-reflective markers). Reliability was assessed using two-way mixed-effects intraclass correlation coefficients (ICC[Formula: see text]) with absolute agreement. Individual-measure ICC values ranged from poor to good across joints and conditions (range: 0.005-0.68). The highest reliability was observed for the right hip external rotation ROM (individual ICC [Formula: see text]; average ICC [Formula: see text], 95% CI: 0.63-0.89). Several measures showed poor reliability, including the right elbow flexion ROM (individual ICC [Formula: see text]) and the minimum angle of the left hip external rotation (individual ICC [Formula: see text]). Confidence intervals were wide throughout. This proof of concept demonstrates that a single-camera AI system can capture general trends in joint angles during simple rehabilitation exercises in healthy adults under controlled conditions. However, reliability is inconsistent and frequently poor, and the system has not been evaluated in patient populations with pathological movement patterns. These findings do not support clinical deployment at this stage. Substantial further development and validation in patient cohorts are required before clinical or home-based use can be considered.