MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-018-4188-1

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2018

Visual acuity in patients with keratoconus: a comparison with matched regular myopic astigmatism.

Mimouni Michael, Najjar Riham, Rabina Gilad, Vainer Igor, Kaiserman Igor

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare uncorrected distance visual acuity (UDVA) and best-corrected distance visual acuity (CDVA) between patients with keratoconus (KC) and matched patients with regular myopic astigmatism.

METHODS

This retrospective study included consecutive patients diagnosed with KC between 2008 and 2013 at Care-Vision Laser Centers, Tel-Aviv, Israel, and matched patients with regular myopic astigmatism. Data included were central corneal thickness (CCT), spherical equivalent (SE), cylinder (CYL), mean keratometric power, maximum keratometric power (Kmax), UDVA, CDVA, and defocus equivalent (DEQ).

RESULTS

The KC group included 734 patients with a mean age of 33.8 ± 9.5 years. The matched, control group included 1462 patients with a mean age of 33.2 ± 9.7 years (p = 0.14). The mean SE and CYL of the KC group were - 3.34 ± 3.29D and - 3.01 ± 1.99D, respectively, compared to - 3.34 ± 2.92D (p = 0.98) and - 2.97 ± 1.35 (p = 0.58). Mean K (46.8 ± 3.3D versus 44.0 ± 1.8D, p < 0.0001) and Kmax (48.4 ± 4.0D versus 45.3 ± 2.0D, p < 0.0001) were statically significant higher in the KC group. CCT was significantly thinner in the KC group (444 ± 49 versus 527 ± 40 μm, p < 0.0001). The KC group had a better UDVA than the non-KC group (1.10 ± 0.68 versus 1.22 ± 0.64 logMAR, p < 0.0001). CDVA was significantly lower in the KC group (p < 0.001).

CONCLUSIONS

For defocus equivalents above 6D, the KC group had better UDVA than the non-KC group in spite of worse CDVA.

Для цитирования: Mimouni Michael, Najjar Riham, Rabina Gilad, Vainer Igor, Kaiserman Igor. Visual acuity in patients with keratoconus: a comparison with matched regular myopic astigmatism.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2018. DOI: 10.1007/s00417-018-4188-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.