MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000001292

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2018

Cornea Full-field Displacement and Strain Measurement in Vivo Using Three-dimensional Digital Image Correlation.

Zhang Xueyong, Wang Qing, Wang Like, Xiao Hong, Zhang Daming, Liao Rongfeng, Zheng Yongping

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: Corneal biomechanics are becoming increasingly important for clinical evaluation and diagnosis, such as in refractive surgery, glaucoma, and keratoconus. We developed and used a new technique to measure the full-field displacement and strain of the cornea under elevated intraocular pressure in vivo.

PURPOSE: In this study, we propose a three-dimensional digital image correlation method for the determination of corneal biomechanical properties.

METHODS

Corneal deformation change on the rabbit eyeball was investigated under different inflation conditions with intraocular pressure levels of 2.3, 3.3, 5.3, and 6.9 kPa in vivo.

RESULTS

The proposed method was able to measure the displacement of the corneal surface and to construct real-time full-field three-dimensional deformation vector fields and strain mapping. The results show that the strain distribution is not uniform on the corneal surface at each intraocular pressure level. Compression strains, rather than extensile strains, are dominant at the corneal apex region.

CONCLUSIONS

This technique has the potential to be used as an assistive tool for the determination of corneal biomechanical properties in ophthalmologic investigations.

Для цитирования: Zhang Xueyong, Wang Qing, Wang Like, Xiao Hong, Zhang Daming, Liao Rongfeng, Zheng Yongping. Cornea Full-field Displacement and Strain Measurement in Vivo Using Three-dimensional Digital Image Correlation.. Optometry and vision science : official publication of the American Academy of Optometry. 2018. DOI: 10.1097/opx.0000000000001292.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.