MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2018/2620784

Медицинская библиотека · BioMed research international · 2018

Time Course of Changes in Simulated Keratometry and Total Corneal Refractive Power after Corneal Collagen Cross-Linking for Progressive Keratoconus.

Takahashi Masahide, Kamiya Kazutaka, Kono Yusuke, Shoji Nobuyuki

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the simulated keratometry (Sim K) and the total corneal refractive power (TCRP) in eyes undergoing conventional corneal cross-linking (CXL).

METHODS

This study comprised 20 eyes of 20 keratoconic patients (14 men and 6 women; median age (25th and 75th percentile), 26.5 (21.8, 38.0) years) who underwent CXL. The Sim K and TCRP were measured with a rotating Scheimpflug system (Pentacam HR, Oculus), preoperatively and 1, 3, 6, and 12 months postoperatively.

RESULTS

The values of Sim K were 52.65 (46.00, 55.70), 52.45 (45.85, 56.88), 51.70 (45.78, 55.83), 51.40 (45.68, 56.80), and 51.25 (46.08, 56.15) D preoperatively and 1, 3, 6, and 12 months postoperatively, respectively. The corresponding figures of TCRP were 52.10 (45.48, 55.08), 51.30 (45.18, 55.20), 50.95 (45.15, 54.50), 50.00 (45.18, 55.08), and 49.80 (45.48, 54.15) D, respectively. The variances of the Sim K and TCRP data were not statistically significant (p=0.994 and p=0.970, respectively, Kruskal-Wallis test). The Sim K was significantly larger than the TCRP before CXL and at 1, 3, 6, and 12 months after CXL (p<0.001, Wilcoxon signed-rank test).

CONCLUSIONS

Not only the Sim K but also TCRP was decreased by approximately 1 D after CXL. The Sim K readings may overestimate the TCRP, even after CXL for progressive keratoconus.

Для цитирования: Takahashi Masahide, Kamiya Kazutaka, Kono Yusuke, Shoji Nobuyuki. Time Course of Changes in Simulated Keratometry and Total Corneal Refractive Power after Corneal Collagen Cross-Linking for Progressive Keratoconus.. BioMed research international. 2018. DOI: 10.1155/2018/2620784.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.