DOI 10.1016/j.jcrs.2018.01.036

Медицинская библиотека · Journal of cataract and refractive surgery · 2018

Relationship between initial corneal hydration and stiffening effects of corneal crosslinking treatment.

Hatami-Marbini Hamed, Jayaram Sandeep M

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To characterize the mechanical property improvement of riboflavin and ultraviolet light corneal crosslinking (CXL) procedure in artificially swollen human and porcine corneas.

SETTING

Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Illinois, USA.

DESIGN

Experimental study.

METHODS

Porcine and human donor corneas were crosslinked at different hydration levels using riboflavin-dextran solutions of different osmolality. Four porcine groups (Hw [hydration in mg H2O/mg dry tissue] = 3.3 ± 0.2 [SD]; 4.0 ± 0.1; 5.1 ± 0.1; 5.6 ± 0.1) and 3 human groups (Hw = 3.2 ± 0.1; 3.9 ± 0.2; 5.3 ± 0.3) were considered. The mechanical properties were measured by uniaxial tensile experiments during which the hydration of samples was the same as the hydration at which they were crosslinked. Tensile properties of 2 porcine groups (Hw = 5.1 ± 0.1; 5.6 ± 0.1) were also measured when their average hydration was lowered to 4.0 mg H2O/mg dry tissue.

RESULTS

The CXL procedure significantly increased tensile properties of both human and porcine samples in each hydration group (P < .05). The improvement in tensile properties was hydration-dependent, that is, samples crosslinked at higher hydration levels showed lower maximum tensile stress. The behavior of samples crosslinked at different initial hydration but tested mechanically at similar hydration showed insignificant difference (P = .7).

CONCLUSION

Increasing the hydration of porcine and human corneal samples before the CXL treatment had insignificant influence on tensile property improvement, as measured by testing specimens at similar hydration.

Для цитирования: Hatami-Marbini Hamed, Jayaram Sandeep M. Relationship between initial corneal hydration and stiffening effects of corneal crosslinking treatment.. Journal of cataract and refractive surgery. 2018. DOI: 10.1016/j.jcrs.2018.01.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.