MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000000490

Медицинская библиотека · Eye & contact lens · 2018

Effects of Preoperative Topometric Indices on Visual Gain After Intracorneal Ring Segment Implantation For Keratoconus.

Utine Canan Asli, Durmaz Engin Ceren, Ayhan Ziya

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To assess the corneal topometric parameters that can be predictive for better visual gain after intracorneal ring segment (ICRS) implantation in eyes with keratoconus.

METHODS

A total of 42 eyes of 32 patients who underwent ICRS implantation at Dokuz Eylul University, Deparment of Ophthalmology, Cornea Divison were included. Changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive errors, and corneal topometric indices measured using Scheimpflug topography (Pentacam, Oculus) were evaluated retrospectively.

RESULTS

After creation of intrastromal tunnels of 5.01±0.03 mm inner diameter, 5.71±0.03 mm outer diameter and at 384.21±34.12 μm depth, 1 or 2 ICRS of 150 to 350 µm thickness and 90 to 210° arc length were implanted. Preoperative UDVA of 0.09±0.10 and CDVA of 0.29±0.14 Snellen lines improved postoperatively to 0.42±0.26 and 0.62±0.24, respectively (P<0.001 for both). Preoperative spherical equivalent of -6.35±4.58D and refractive astigmatism of -5.89±2.40D decreased to -3.59±3.86 and -2.25±1.66D, retrospectively (P<0.001 for both). Strong negative correlations were detected between preoperative mean simulated keratometry (SimKavg)/index of surface variance (ISV) and changes in UDVA/CDVA (P<0.01, for all). Postoperative change in ISV was positively correlated with thicknesses of implanted rings. Change in topographical keratoconus classification was positively and change in index of vertical asymmetry was negatively correlated with number of implanted rings (P<0.05 for all).

CONCLUSIONS

Preoperative ISV value seems to be beneficial in predicting visual gain after ICRS implantation, in addition to SimKavg. Future work on new nomograms for ICRS selection that include ISV, besides refractive, topographic, and cone location data, is warranted.

Для цитирования: Utine Canan Asli, Durmaz Engin Ceren, Ayhan Ziya. Effects of Preoperative Topometric Indices on Visual Gain After Intracorneal Ring Segment Implantation For Keratoconus.. Eye & contact lens. 2018. DOI: 10.1097/icl.0000000000000490.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.