Pirhadi Shiva, Mohammadi Neda, Mosavi Seyed Aliasghar, Daryabari Hashem, Aghamollaei Hossein, Jadidi Khosrow
Аннотация
BACKGROUND: This paper seeks to evaluate the depth and outcomes of MyoRing implantation using two mechanical dissection procedures including: PocketMaker microkeratome in opposition to the Melles hook method.
METHODS: This retrospective study was carried out on 39 eyes of 38 keratoconus patients (28 male and 10 female) with the mean age of [Formula: see text] years and had undergone MyoRing implantation by the two mentioned methods. The MyoRing was inserted into the corneal pocket which was made manually in 18 eyes (Melles hook group) or with PocketMaker microkeratome in 21 eyes (PocketMaker group). The mean follow up time was [Formula: see text] months with pre-operative and post-operative ophthalmic examination including uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), keratometry readings and central corneal thickness measurement. AS-OCT (Casia, SS-1000, Tomey, Nagoya, Japan) imaging was used to measure MyoRing insertion depth, exactly.
RESULTS: Pre-operative and post-operative UCVA (LogMAR) mean change for the PocketMaker and Melles hook groups were recorded at 0.75 ± 0.32 and 0.78 ± 0.33, respectively. Similarly, BCVA (LogMAR) mean change were 0.27 ± 0.22 and 0.23 ± 0.22. Mean keratometry (Kmean) change were 6.06 ± 4.18 and 6.56 ± 3.55 respectively. UCVA change (P = 0.767), BCVA change (P = 0.77) and Kmean change (P = 0.693) showed that there was no statistically significant difference between both groups for any parameter. Depth measurements achieved from AS-OCT images showed that there was no statistically significant difference in pocket depth between two methods of MyoRing implantation (P = 0.413).
CONCLUSIONS: The results of Myoring implantation outcomes using mechanical dissection via PocketMaker microkeratome as against Melles hook are comparable.
METHODS: This retrospective study was carried out on 39 eyes of 38 keratoconus patients (28 male and 10 female) with the mean age of [Formula: see text] years and had undergone MyoRing implantation by the two mentioned methods. The MyoRing was inserted into the corneal pocket which was made manually in 18 eyes (Melles hook group) or with PocketMaker microkeratome in 21 eyes (PocketMaker group). The mean follow up time was [Formula: see text] months with pre-operative and post-operative ophthalmic examination including uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), keratometry readings and central corneal thickness measurement. AS-OCT (Casia, SS-1000, Tomey, Nagoya, Japan) imaging was used to measure MyoRing insertion depth, exactly.
RESULTS: Pre-operative and post-operative UCVA (LogMAR) mean change for the PocketMaker and Melles hook groups were recorded at 0.75 ± 0.32 and 0.78 ± 0.33, respectively. Similarly, BCVA (LogMAR) mean change were 0.27 ± 0.22 and 0.23 ± 0.22. Mean keratometry (Kmean) change were 6.06 ± 4.18 and 6.56 ± 3.55 respectively. UCVA change (P = 0.767), BCVA change (P = 0.77) and Kmean change (P = 0.693) showed that there was no statistically significant difference between both groups for any parameter. Depth measurements achieved from AS-OCT images showed that there was no statistically significant difference in pocket depth between two methods of MyoRing implantation (P = 0.413).