m+Medelevator.RU
← Поиск публикаций
Journal of pediatric surgery · 2017

A pilot study of ultrasound elastography as a non-invasive method to monitor liver disease in children with short bowel syndrome.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lodwick Daniel, Dienhart Molly, Cooper Jennifer N, Fung Bonita, Lopez Joseph, Smith Sally, Warren Patrick, Balint Jane, Minneci Peter C

Аннотация

BACKGROUND: Our objective was to evaluate the accuracy of acoustic radiation force impulse (ARFI) elastography in determining extent of liver fibrosis in pediatric patients with short bowel syndrome (SBS).

METHODS: This prospective cohort study included pediatric patients with SBS who underwent ultrasound with ARFI measurements of shear wave speed (SWS) and liver biopsy within 30days of each other between 12/2014-9/2015. The mean and median SWS were compared to the stage of fibrosis. Receiver operating characteristic curves (ROC) were also generated to assess the classification accuracy of SWS measurements for mild (F0-F1) versus moderate/severe fibrosis (F2-F4).

RESULTS: Twelve patients were included with median age 1.4years and median weight 11.3kg. The median direct bilirubin level was 0.3mg/dL at the time of biopsy. On liver biopsy, 6 patients had mild fibrosis (F1), 3 had septal fibrosis (F3), and 3 had cirrhosis (F4). The area under the ROC curve for elastography to differentiate moderate/severe liver fibrosis from mild disease was 0.83 (95CI 0.58-1.00) and 0.86 (95CI 0.63-1.00) for the median SWS and mean SWS, respectively.

CONCLUSIONS: These early results suggest that ARFI ultrasound elastography may be a reliable non-invasive method to monitor liver fibrosis in pediatric patients with SBS.

TYPE OF STUDY: Prospective observational cohort.

LEVEL OF EVIDENCE: 3.