Robotic Redo Mitral Valve Replacement and Atrioventricular Groove Pseudoaneurysm Repair.
Аннотация
We report the use of robot-assisted right thoracotomy in the management of a patient who presented with acute-on-chronic congestive heart failure, associated with a contained atrioventricular dissection and 2 prior mitral valve replacements. Our patient had evidence of a contained rupture, as represented by preoperative cross-sectional imaging. The anatomic sequela from this was a ventricular pseudoaneurysm, which was likely survivable due to adhesions from prior operations buttressing the margins of the defect. Expansion of the pseudoaneurysm likely contributed to the dehiscence of the prosthesis. Our case illustrates an unprecedented resolution of a serious complication, managed effectively and efficiently by a robot-assisted procedure. With a successful outcome of totally endoscopic and robot-assisted repair, we demonstrate the versatility of minimally invasive techniques in addressing complicated anatomy as well as a surgical field scarred by multiple prior surgeries.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.