Prevention of nostril lacerations in endonasal drilling procedures by use of a conventional protective ear speculum.

Dubach Patrick, Michailidou Efterpi, Waser Manuel, Friedrich Hergen, Huth Markus, Caversaccio Marco

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Injuries of the nasal vestibular skin caused by the rotating burr shafts can represent a tedious complication following endonasal drilling and is experienced sooner or later by every rhino-surgeon.

MATERIAL AND

METHODS

To protect the nasal entrance from laceration by the free rotating drill shaft we position an otology speculum in the nasal entrance. The speculum is held in place by the scrub nurse during the critical phase of bone drilling.

RESULTS

Following the introduction of the ear speculum protection, we successfully treated our dacryocystostamia procedures (n = 27) and median maxillectomia procedures (n = 6) without any further soft tissue erosions.

DISCUSSION: Preventive measures for injuries by endonasal drilling procedures are not reported extensively in literature. This stands in contrast to the fact that these injuries are prone to cause significant suffering as amply described in the case of nostril laceration due to nasogastric intubation or nasogastric feeding tubes.

CONCLUSION

The use of a readily available, reusable ear speculum in endonasal drill application eliminated the complication of nasal entrance lacerations throughout our institution, hitherto.

Для цитирования: Dubach Patrick, Michailidou Efterpi, Waser Manuel, Friedrich Hergen, Huth Markus, Caversaccio Marco. Prevention of nostril lacerations in endonasal drilling procedures by use of a conventional protective ear speculum.. American journal of otolaryngology. 2024. DOI: 10.1016/j.amjoto.2024.104319.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.