MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2463/mrms.mp.2025-0164

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2026

Improvement in Image Quality and Efficiency of Non-contrast Thoracic MR Angiography: Comparison of a Highly Accelerated Dixon-based Technique with the Conventional Fat-suppressed Technique.

Xing Jingyi, Higuchi Satoshi, Mori Ryuichi, Ichinoseki Yuki, Komori Yoshiaki, Manabe Akihiro, Giese Daniel, Schmidt Michaela, Kamada Hiroki, Takagi Hidenobu, Takase Kei, Ota Hideki

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the image quality and acquisition time of thoracic great vessels using a novel, 3D isotropic non-contrast-enhanced MR angiography that combines respiratory compensation, electrocardiogram-triggering, compressed sensing, and Dixon water-fat separation at 3T (CS-MRA) to a conventional MRA employing parallel imaging and spectral attenuated inversion recovery (cMRA).

METHODS

This study included 20 healthy volunteers and 19 patients with thoracic vascular diseases. All scans were performed on a 3T MRI scanner using a T2-prepared 3D fast low angle shot (FLASH) sequence. Visual image quality of thoracic great vessels was assessed using a 4-point scale. Quantitative parameters including SNR, contrast-to-noise ratio (CNR), contrast ratio (CR), and coefficient of variation (CV) were evaluated. Aortic diameters were measured, and reproducibility was assessed using Bland-Altman analysis and the intraclass correlation coefficient (ICC). Image acquisition times were also compared.

RESULTS

Visual assessment demonstrated significantly higher scores with CS-MRA compared to cMRA across all evaluated thoracic vessels in both volunteers and patients (median score: 3 vs. 2, P < 0.05). Quantitative analysis showed that CS-MRA yielded significantly higher SNR, CNR, and CR (P < 0.05 for all), along with better signal homogeneity (lower CV). CS-MRA showed excellent intra- and inter-observer agreement for aortic diameter measurements, with ICCs ≥ 0.91 in volunteers and ≥ 0.95 in patients. CS-MRA also achieved significantly shorter acquisition times (volunteers: 5.3 ± 1.4 min vs. 6.0 ± 1.7 min, P < 0.01; patients: 5.1 [4.6-6.3] min vs. 6.9 [5.0-9.6] min, P < 0.01).

CONCLUSION

CS-MRA provides superior image quality, comparable measurement reproducibility, and significantly reduced acquisition times compared to cMRA. These findings support the clinical utility of CS-MRA as an efficient and reliable non-contrast technique for thoracic vascular evaluation.

Для цитирования: Xing Jingyi, Higuchi Satoshi, Mori Ryuichi, Ichinoseki Yuki, Komori Yoshiaki, Manabe Akihiro, Giese Daniel, Schmidt Michaela, Kamada Hiroki, Takagi Hidenobu, Takase Kei, Ota Hideki. Improvement in Image Quality and Efficiency of Non-contrast Thoracic MR Angiography: Comparison of a Highly Accelerated Dixon-based Technique with the Conventional Fat-suppressed Technique.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2026. DOI: 10.2463/mrms.mp.2025-0164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.