MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/nu16152427

Медицинская библиотека · Nutrients · 2024

Diagnostic Accuracy of IgA Anti-Transglutaminase Assessed by Chemiluminescence: A Systematic Review and Meta-Analysis.

Pjetraj Dorina, Pulvirenti Alfredo, Moretti Marco, Gatti Simona, Catassi Giulia Naspi, Catassi Carlo, Lionetti Elena

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

A new chemiluminescence immunoassay method (CLIA) for detecting IgA anti-transglutaminase (atTG IgA) in celiac disease (CD) has prompted inquiries into its diagnostic performance. We conducted a systematic review and meta-analysis comparing CLIA with traditional enzyme-linked immunosorbent assay (ELISA) and fluorescence enzyme immunoassay (FEIA). We searched PubMed, Medline, and Embase databases up to March 2024. The diagnostic references were intestinal biopsy and ESPGHAN guidelines. We calculated the sensitivity and specificity of atTG IgA assessed by CLIA and the odds ratio (OR) between the assays. Eleven articles were eligible for the systematic review and seven for the meta-analysis. Sensitivity and specificity of atTG IgA CLIA-assay were 0.98 (95% CI, 0.95-0.99) and 0.97 (95% CI, 0.94-0.99), respectively. The sensitivity of atTG IgA antibody detection did not significantly vary across the three assay modalities examined (CLIA vs. ELISA OR: 1.08 (95% CI, 0.56-2.11; p = 0.8); CLIA vs. FEIA OR: 6.97 (95% CI, 0.60-81.03; p = 0.1). The specificity of atTG IgA assessed by FEIA was higher than for CLIA (OR 0.17 (95% CI, 0.05-0.62); p < 0.007). According to the systematic review, normalization of atTG IgA levels in CD patients following a gluten-free diet was delayed when using CLIA compared to ELISA and FEIA methods. Conflicting findings were reported on the antibody threshold to use in order to avoid biopsy confirmation.

Для цитирования: Pjetraj Dorina, Pulvirenti Alfredo, Moretti Marco, Gatti Simona, Catassi Giulia Naspi, Catassi Carlo, Lionetti Elena. Diagnostic Accuracy of IgA Anti-Transglutaminase Assessed by Chemiluminescence: A Systematic Review and Meta-Analysis.. Nutrients. 2024. DOI: 10.3390/nu16152427.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.