European heart journal. Case reports · 2022

Tip detection-antegrade dissection and reentry using intravascular ultrasound in chronic total occlusion intervention: first human case report.

Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Suzuki Satoshi, Okamura Atsunori, Nagai Hiroyuki, Iwakura Katsuomi

Аннотация

BACKGROUND: It has been considered impossible to perform antegrade dissection and reentry (ADR) by simply puncturing with a guidewire using the intravascular ultrasound (IVUS) observation without the support of the Stingray system.

CASE SUMMARY: A 78-year-old man suffered from effort angina pectoris due to a chronic total occlusion (CTO) lesion in the left circumflex coronary artery. A retry percutaneous coronary intervention for the CTO lesion was attempted at our hospital. The J-CTO score was 3. The first guidewire entered the subintimal space. We moved onto Stingray-ADR using the angiographic observation, but the guidewire could not be led into the true lumen. AnteOwl WR-IVUS (AO-IVUS) observation revealed a distal true lumen in which the inner lumen was maintained 5 mm beyond the CTO exit. We decided to perform the tip detection-ADR using the AO-IVUS observation. The tip detection method allowed the tip of the penetration wire to puncture the wall between the subintima and the true lumen in an exactly vertical direction, resulting in the successful creation of a reentry point. The CTO lesion was dilated with one drug-eluting stent, and normal antegrade blood flow was achieved.

DISCUSSION: Since the tip detection method enables accurate punctures, it may allow for ADR by simply puncturing using a guidewire. Due to this method being performed using the IVUS observation, it is likely more reliable than Stingray-ADR using the angiographic observation.