MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/cjn.2015.391

Медицинская библиотека · The Canadian journal of neurological sciences. Le journal canadien des sciences neurologiques · 2016

StatNet Electroencephalogram: A Fast and Reliable Option to Diagnose Nonconvulsive Status Epilepticus in Emergency Setting.

Ladino Lady Diana, Voll Alexandra, Dash Dianne, Sutherland Wes, Hernández-Ronquillo Lizbeth, Téllez-Zenteno Jose Francisco, Moien-Afshari Farzad

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The StatNet electrode set is a system that can be applied by a non-electroencephalogram (EEG) technologist after minimal training. The primary objectives of this study are to assess the quality and reliability of the StatNet recordings in comparison to the conventional EEG.

METHODS

Over 10 months, 19 patients with suspected nonconvulsive status epilepticus were included from university hospital emergency settings. Each patient received a StatNet EEG by a trained epilepsy fellow and a conventional EEG by registered technologists. We compared the studies in a blinded fashion, for the timeframe from EEG order to the setup time, start of acquisition, amount of artifact, and detection of abnormalities. The nonparametric Mann-Whitney two-sample t test was used for comparisons. The kappa score was used to assess reliability.

RESULTS

Mean age of patients was 61±16.3 (25-93) years. The inter-observer agreement for detection of abnormal findings was 0.83 for StatNet and 0.75 for conventional EEG. Nonconvulsive status epilepticus was detected in 10% (2/19) in both studies. The delay from the time of EEG requisition to acquisition was shorter in the StatNet (22.4±2.5 minutes) than the conventional EEG (217.7±44.6 minutes; p<0.0001). The setup time was also shorter in the StatNet (9.9±0.8 minutes) compared with the conventional EEG (17.8±0.8 minutes; p<0.0001). There was no difference in the percentage of artifact duration between the two studies (p=0.89).

CONCLUSION

This study demonstrates that StatNet EEG is a practical and reliable tool in the emergency setting, which reduces the delay of testing compared with conventional EEG, without significant compromise of study quality.

Для цитирования: Ladino Lady Diana, Voll Alexandra, Dash Dianne, Sutherland Wes, Hernández-Ronquillo Lizbeth, Téllez-Zenteno Jose Francisco, Moien-Afshari Farzad. StatNet Electroencephalogram: A Fast and Reliable Option to Diagnose Nonconvulsive Status Epilepticus in Emergency Setting.. The Canadian journal of neurological sciences. Le journal canadien des sciences neurologiques. 2016. DOI: 10.1017/cjn.2015.391.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.