MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/1570162x17666190712125606

Медицинская библиотека · Current HIV research · 2019

Performance of a Modified In-House HIV-1 Avidity Assay among a Cohort of Newly Diagnosed HIV-1 Infected Individuals and the Effect of ART on the Maturation of HIV-1 Specific Antibodies.

Alex Diviya, Raj Williams Tennison Inba, Sachithanandham Jaiprasath, Prasannakumar Swaminathan, Demosthenes John Paul, Ramalingam Veena Vadhini, Victor Punitha John, Rupali Priscilla, Fletcher Gnanadurai John, Kannangai Rajesh

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Viral kinetics impact humoral immune response to HIV; antibody avidity testing helps distinguish recent (<6 months) and long-term HIV infection. This study aims to determine the frequency of recent HIV-1 infection among clients attending ICTC (Integrated Counselling and Testing Centre) using a commercial EIA, to correlate it with a modified in-house avidity assay and to study the impact of ART on anti-HIV-1 antibody maturation.

METHODS

Commercial LAg Avidity EIA was used to detect antibody avidity among 117 treatment naïve HIV-1 infected individuals. A second-generation HIV ELISA was modified for in-house antibody avidity testing and cutoff was set based on Receiver Operating Characteristic (ROC) analysis. Archived paired samples from 25 HIV-1 infected individuals before ART and after successful ART; samples from 7 individuals responding to ART and during virological failure were also tested by LAg Avidity EIA.

RESULTS

Six individuals (5.1%) were identified as recently infected by a combination of LAg avidity assay and HIV-1 viral load testing. The modified in-house avidity assay demonstrated sensitivity and specificity of 100% and 98.2%, respectively, at AI=0.69 by ROC analysis. Median ODn values of individuals when responding to ART were significantly lower than pre-ART [4.136 (IQR 3.437- 4.827) vs 4.455 (IQR 3.748-5.120), p=0.006] whereas ODn values were higher during virological failure [4.260 (IQR 3.665 - 4.515) vs 2.868 (IQR 2.247 - 3.921), p=0.16].

CONCLUSION

This modified in-house antibody avidity assay is an inexpensive method to detect recent HIV-1 infection. ART demonstrated significant effect on HIV-1 antibody avidity owing to changes in viral kinetics.

Для цитирования: Alex Diviya, Raj Williams Tennison Inba, Sachithanandham Jaiprasath, Prasannakumar Swaminathan, Demosthenes John Paul, Ramalingam Veena Vadhini, Victor Punitha John, Rupali Priscilla, Fletcher Gnanadurai John, Kannangai Rajesh. Performance of a Modified In-House HIV-1 Avidity Assay among a Cohort of Newly Diagnosed HIV-1 Infected Individuals and the Effect of ART on the Maturation of HIV-1 Specific Antibodies.. Current HIV research. 2019. DOI: 10.2174/1570162x17666190712125606.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.