MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00270-025-04293-3

Медицинская библиотека · Cardiovascular and interventional radiology · 2026

Automatic Bone Removal in CBCT Scans of the Body Trunk: Thorax, Abdomen, and Pelvis.

Winther Hinrich, Maschke Sabine, Becker Lena, Dewald Cornelia, Eicke Marcel, Jakobs Tobias, Kloeckner Roman, Schmid Axel, Wacker Frank, Meyer Bernhard

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate a fully automated bone removal software for cone beam computed tomography (CBCT) of the thorax, abdomen, and pelvis, enhancing vascular visualization by eliminating bone interference and improving diagnostic quality.

MATERIAL AND

METHODS

1035 CBCT scans from adults age 66.5 ± 11.9 18-87 years (mean ± std min-max) across nine centers were retrospectively analyzed, divided into training (n = 855, 515 abdomen, 229 pelvis, 111 thorax) and testing (n = 180, 60 for each region, 114 male, 53 female, 13 unknown). Manual bone segmentation was performed using ITK-SNAP. A modified 3D U-Net was trained and clinically evaluated through multireader analysis using ordinal scales from 1 (perfect) to 4 (not usable) bone subtraction (B-rating) and erosion of non-target structures (V-rating) in addition to a vessel assessment (VA-rating), categorizing the subtracted image as "better" (1), "same" (2), or "worse" (3). Quantitative metrics include Sørensen-Dice coefficient and intersection over union (IoU).

RESULTS

The software demonstrated high accuracy with a B-rating of 1.01 ± 0.07 and a V-rating of 1.02 ± 0.13, indicating minimal erosion of non-target structures. A VA-rating of 1.0 ± 0 suggests an improved vessel assessment and the depiction of contrast material deposition, enhancing the diagnostic quality of CBCT images. Quantitative analysis closely matched the manual expert delineation (Sørensen-Dice coefficient 0.95 ± 0.02, IoU of 0.9 ± 0.03).

CONCLUSION

The software provides robust, fully automated bone removal in CBCT scans. This technology may enhance vascular system visualization without compromising non-target structures, potentially improving the accuracy and efficiency of interventional and diagnostic radiology procedures.

Для цитирования: Winther Hinrich, Maschke Sabine, Becker Lena, Dewald Cornelia, Eicke Marcel, Jakobs Tobias, Kloeckner Roman, Schmid Axel, Wacker Frank, Meyer Bernhard. Automatic Bone Removal in CBCT Scans of the Body Trunk: Thorax, Abdomen, and Pelvis.. Cardiovascular and interventional radiology. 2026. DOI: 10.1007/s00270-025-04293-3.