DOI 10.1007/s10334-025-01317-4
Abdominal T1 relaxation times at 7T.
Аннотация
OBJECTIVE
To quantify the T1 relaxation times at 7T for key abdominal organs and tissues, including the liver, kidney, spleen, and skeletal paraspinal muscles.
MATERIALS AND
METHODS
T1 mapping was performed on a 7T whole-body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx (B1+ shimming) was applied to maximize B1+ magnitude in the target region. For each T1 map, data were collected using eight snapshot gradient-echo inversion recovery sequences during breath holding. Voxel-wise T1 values were calculated based on DICOM data using exponential model fitting.
RESULTS
Mean abdomen T1 values and corresponding coefficients of variation across the group were: 1829 ± 60 ms, 3.3% for the kidney cortex; 2619 ± 83 ms, 3.2% for the kidney medulla; 1378 ± 48 ms, 3.5% for the liver; 1954 ± 28 ms, 1.4% for the skeletal paraspinal muscle; 1770 ± 36 ms, 2.0% for the spleen.
CONCLUSION
In this study, we quantified the T1 relaxation times at 7T for key abdominal organs and tissues, including the liver, kidney, spleen, and skeletal paraspinal muscle. To achieve this, pTx was applied to mitigate B1+ dropouts in the target regions. The B1+ insensitive snapshot gradient-echo inversion recovery method was utilized to acquire accurate and reproducible T1 maps.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.