3D Latent Diffusion Model for MR-Only Radiotherapy: Accurate and Consistent Synthetic CT Generation.

Mahdi Mohammed A, Al-Shalabi Mohammed, Alnfrawy Ehab T, Elbarougy Reda, Hadi Muhammad Usman, Ali Rao Faizan

СтатьяПеревод пока не подготовлен

Аннотация

Background

The clinical imperative to reduce patient ionizing radiation exposure during diagnosis and treatment planning necessitates robust, high-fidelity synthetic imaging solutions. Current cross-modal synthesis techniques, primarily based on GANs and deterministic CNNs, exhibit instability and critical errors in modeling high-contrast tissues, thereby hindering their reliability for safety-critical applications such as radiotherapy.

Objectives

Our primary objective was to develop a stable, high accuracy framework for 3D Magnetic Resonance Imaging (MRI) to Computed Tomography (CT) synthesis capable of generating clinically equivalent synthetic CTs (sCTs) across multiple anatomical sites.

Methods

We introduce a novel 3D Latent Diffusion Model (3DLDM) that operates in a compressed latent space, mitigating the computational burden of 3D diffusion while leveraging the stability of the denoising objective.

Results

Across the Head & Neck, Thorax, and Abdomen, the 3DLDM achieved a Mean Absolute Error (MAE) of 56.44 Hounsfield Units (HU). This result demonstrates a significant 3.63% reduction in overall error compared to the strongest adversarial baseline, CycleGAN (MAE = 60.07 HU, p < 0.05), a 10.76% reduction compared to NNUNet (MAE = 67.20 HU, p < 0.01), and a 20.79% reduction compared to the transformer-based SwinUNeTr (MAE = 77.23 HU, p < 0.0001). The model also achieved the highest structural similarity (SSIM = 0.885 ± 0.031), significantly exceeding SwinUNeTr (p < 0.0001), NNUNet (p < 0.01), and Pix2Pix (p < 0.0001). Likewise, the 3D-LDM achieved the highest peak signal-to-noise ratio (PSNR = 29.73 ± 1.60 dB), with statistically significant gains over CycleGAN (p < 0.01), NNUNet (p < 0.001), and SwinUNeTr (p < 0.0001).

Conclusions

This work validates a scalable, accurate approach for volumetric synthesis, positioning the 3DLDM to enable MR-only radiotherapy planning and accelerate radiation-free multi-modal imaging in the clinic.

Для цитирования: Mahdi Mohammed A, Al-Shalabi Mohammed, Alnfrawy Ehab T, Elbarougy Reda, Hadi Muhammad Usman, Ali Rao Faizan. 3D Latent Diffusion Model for MR-Only Radiotherapy: Accurate and Consistent Synthetic CT Generation.. Diagnostics (Basel, Switzerland). 2025. DOI: 10.3390/diagnostics15233010.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.