European heart journal. Cardiovascular Imaging · 2025

Imaging-based method to quantify left ventricular diastolic pressures.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Smiseth Otto A, Fernandes Joao F, Ohte Nobuyuki, Wakami Kazuaki, Donal Erwan, Remme Espen W, Lamata Pablo

Аннотация

AIMS: To establish an imaging-based method to quantify left ventricular (LV) diastolic pressures.

METHODS AND RESULTS: In 115 patients suspected of coronary artery disease, LV pressure was measured by micromanometers and images by echocardiography. LV filling pressure was measured as LV pre-atrial contraction pressure (pre-A PLV). Based on previous observations, we hypothesized that pre-A PLV approximates the sum of minimum PLV and maximum transmitral pressure difference. Parameters used for pressure estimates included LV volumes and strain, left atrial strain, mitral flow velocities, systolic arterial cuff pressure, and body mass index. Minimum PLV was estimated by predictors identified in a derivative cohort (n = 81). Mitral pressure difference was calculated by a simplified Navier-Stokes equation. Accuracy of estimates of minimum PLV, pre-A PLV, and end-diastolic PLV was investigated in a testing cohort (n = 19). Patient-specific LV diastolic pressure curves were constructed by adjusting a reference curve according to pressure estimates at key diastolic events. There was good agreement between estimated and measured pre-A PLV: bias 0.0, limits of agreement < 3.1 mmHg (±1.96 SD). Estimated minimum PLV and end-diastolic PLV also showed good agreement with measured pressures. Furthermore, there was good agreement between measured and estimated LV diastolic pressure curves, quantified as mean LV diastolic pressure: bias 0.2, limits of agreement < 3.2 mmHg.

CONCLUSION: The proposed non-invasive method provided estimates of minimum PLV, pre-A PLV, and end-diastolic PLV, each reflecting different features of diastolic function. Additionally, it provided an estimate of the LV diastolic pressure curve. Validation in larger populations with different phenotypes is necessary to determine the validity of the method in clinical practice.