DOI 10.1016/j.jvir.2020.08.027

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2020

Impact of Intrahepatic Venovenous Shunt on Hepatic Venous Pressure Gradient Measurement.

Ma Jingqin, Gong Ximing, Luo Jianjun, Gu Junying, Yan Zhiping, Zhang Wen, Li Changyu, Zhang Zihan, Yang Minjie

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To quantitatively analyze the impact of intrahepatic venovenous shunt (IHVS) on hepatic venous pressure gradient (HVPG) measurement.

MATERIALS AND

METHODS

From 2015 to 2019, 222 HVPG measurements performed during transjugular intrahepatic portosystemic shunt creation were eligible for this study. Digital subtraction angiography (DSA) software color-coded each pixel of a two-dimensional DSA series by time-intensity curve to classify IHVS. Different degrees of IHVS were found in 36.5% of patients (81/222). Mild IHVS was found in 10.8% of patients (24/222), moderate IHVS was found in 10.8% of patients (24/222), and severe IVHS was found in 14.9% of patients (33/222).

RESULTS

Mean wedged hepatic vein pressure (WHVP) and HVPG were significantly lower in patients with IHVS compared with patients without IHVS (WHVP: 17.78 mm Hg ± 7.00 vs 24.89 mm Hg ± 8.69, P = .001; HVPG: 11.93 mm Hg ± 5.76 vs 18.6 mm Hg ± 6.85, P < .001). Mild IHVS had little effect on WHVP and HVPG. Mean WHVP and HVPG were 11 mm Hg lower in patients with moderate IHVS (WHVP: 20.38 mm Hg ± 8.38 vs 31.5 mm Hg ± 9.39, P = .026; HVPG: 13.88 mm Hg ± 6.33 vs 25.00 mm Hg ± 9.81, P < .001) and 15 mm Hg lower in patients with severe IHVS (WHVP: 13.45 mm Hg ± 5.28 vs 28.64 mm Hg ± 6.38, P = .017; HVPG: 8.27 mm Hg ± 3.85 vs 23.45 mm Hg ± 6.95, P < .001) than mean portal vein pressure and portal vein gradient.

CONCLUSIONS

For patients with moderate or severe IHVS, HVPG might greatly underestimate the actual value of portal vein pressure, and the portal vein should be catheterized to measure portal pressure.

Для цитирования: Ma Jingqin, Gong Ximing, Luo Jianjun, Gu Junying, Yan Zhiping, Zhang Wen, Li Changyu, Zhang Zihan, Yang Minjie. Impact of Intrahepatic Venovenous Shunt on Hepatic Venous Pressure Gradient Measurement.. Journal of vascular and interventional radiology : JVIR. 2020. DOI: 10.1016/j.jvir.2020.08.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.