m+Medelevator.RU
← Поиск публикаций
Ophthalmic research · 2017

Ganglion Cell-Inner Plexiform Layer Thickness in Different Glaucoma Stages Measured by Optical Coherence Tomography.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zivkovic Maja, Dayanir Volkan, Zlatanovic Marko, Zlatanovic Gordana, Jaksic Vesna, Jovanovic Predrag, Radenkovic Marija, Djordjevic-Jocic Jasmina, Stankovic-Babic Gordana, Jovanovic Svetlana

Аннотация

AIM: To compare ganglion cell (GCL) and inner plexiform layer (IPL) thickness in patients at different stages of primary open-angle glaucoma (POAG), determine their sensitivity and specificity values, and correlate thickness values with mean deviations (MD).

METHODS: This prospective, cross- sectional study was conducted in a group of patients with confirmed POAG who were compared to an age- and gender-matched control group. Glaucomatous damage was classified according to the Hodapp-Parrish-Anderson scale: glaucoma stage 1 (early), glaucoma stage 2 (moderate), and glaucoma stage 3 (severe). The average, minimum, and all 6 sectoral (superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal) GCL + IPL thicknesses were measured and compared between groups.

RESULTS: The average GCL + IPL thickness of 154 eyes of 93 patients in glaucoma stages 1, 2, 3, and 94 eyes of 47 persons in the control group were 76.79 ± 8.05, 65.90 ± 7.92, 57.38 ± 10.00, and 86.01 ± 3.68 μm, respectively. There were statistically significant differences in the average, minimum, and all 6 sectoral GCL + IPL values among the groups. The areas under the receiver operating characteristic curve for average and minimum GCL + IPL thickness values were 0.93 and 0.94, respectively, sensitivity 91.5 and 88.3%, and specificity 98.9 and 100%, respectively. Both thickness values showed significant correlations with MD. Each micrometer decrease in the average GCL + IPL thickness was associated with a 0.54-dB loss in MD.

CONCLUSION: GCL + IPL layer thickness is a highly specific and sensitive parameter in differentiating glaucomatous from healthy eyes showing progressive damage as glaucoma worsens. Loss of this layer is highly correlated with overall loss of visual field sensitivity.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты