MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2017/9364910

Медицинская библиотека · Journal of ophthalmology · 2017

Evaluation of Bleb Morphology and Reduction in IOP and Glaucoma Medication following Implantation of a Novel Gel Stent.

Fea Antonio Maria, Spinetta Roberta, Cannizzo Paola Maria Loredana, Consolandi Giulia, Lavia Carlo, Aragno Vittoria, Germinetti Francesco, Rolle Teresa

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the efficacy and safety of the Xen Gel Stent and provide a macro- and microscopic analyses of bleb morphology.

METHODS

A prospective 12-month study on patients with primary open-angle glaucoma. Patients underwent implantation of the XEN Gel Stent (Allergan INC, Dublin, Ireland) either alone or combined with a cataract surgery. Biomicroscopy, in vivo confocal microscopy (IVCM), and anterior segment-optical coherence tomography (AS-OCT) were used to assess bleb morphology. Safety parameters were adverse events, best corrected visual acuity, visual field, and corneal endothelial cell loss. A postoperative IOP ≤ 18 mmHg without or on medications was respectively defined as complete and qualified success while an IOP ≥ 18 mmHg was defined as failure.

RESULTS

Twelve eyes of 11 patients were evaluated. At one year, 5 out of 10 patients available achieved a complete success while five were qualified success. AS-OCT showed that bleb wall reflectivity was significantly higher in the failure group; IVCM revealed that stromal density was significantly lower in the success group. No safety issues were recorded.

CONCLUSION

Implantation of the XEN Gel Stent appears to be a safe and effective procedure. AS-OCT and IVCM may be helpful in bleb assessment.

Для цитирования: Fea Antonio Maria, Spinetta Roberta, Cannizzo Paola Maria Loredana, Consolandi Giulia, Lavia Carlo, Aragno Vittoria, Germinetti Francesco, Rolle Teresa. Evaluation of Bleb Morphology and Reduction in IOP and Glaucoma Medication following Implantation of a Novel Gel Stent.. Journal of ophthalmology. 2017. DOI: 10.1155/2017/9364910.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.