MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjci/jeae331

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2025

The effect of increased vascular afterload measures on flow rate and survival in severe aortic stenosis.

Hungerford Sara L, Song Ning, Loo Brandon, Sritharan Hari, Rye Eleanor, Everett Kay, Jabbour Andrew, Hayward Christopher, Kapur Navin K, Muller David W M, Adji Audrey I

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Although an association between the systemic circulation and transaortic flow rate (TFR) is frequently hypothesized in patients with aortic stenosis (AS), it has not been demonstrated previously. We sought to explore the relationship between blood pressure (BP), vascular afterload measures, clinical history of hypertension, TFR, and survival in patients with severe AS (aortic valve area ≤ 1 cm²).

METHODS AND

RESULTS

We studied 323 patients ≥ 65 years (110 prospective, 213 registry analysis) who underwent transcatheter aortic valve replacement over a 5-year period. Aortic flow was obtained by Doppler echocardiography, with TFR calculated using a mathematical derivation method. A BP ≥ 140/90 mmHg and/or mean arterial pressure ≥ 90 mmHg was considered hypertensive. Simultaneous pressure-flow analysis demonstrated that higher systolic BP (ß -0.545; P = 0.01†), pulse pressure (ß -0.545; P = 0.01†), vascular resistance (ß -0.02; P = 0.041), characteristic impedance (ß -0.27; P = 0.01), and lower arterial compliance (ß 32.73; P < 0.001†) were associated with reduced TFR in linear regression. In registry analysis, TFR was lower in those with a history of hypertension (223 ± 67 vs. 244 ± 77 mL/s; r -0.138; P = 0.045), coronary artery disease (CAD, P < 0.01), dialysis dependency (P < 0.01), and with increased anti-hypertensive medication use (P = 0.04), of which CAD (ß -28.5; P = 0.08†) and dialysis dependency (ß -68.5; P = 0.04†) remained significant in linear regression. A TFR ≤ 210 mL/s in normotensive patients was the strongest predictor of mortality (73.3% vs. 86.7%; P = 0.043; † denotes adjusted).

CONCLUSION

Elevated vascular afterload measures and comorbidities linked to arteriosclerosis and/or degenerative aortic stiffening independently reduce flow rates in severe AS. A TFR ≤ 210 mL/s predicts mortality but improves with BP assessment during evaluation.

Для цитирования: Hungerford Sara L, Song Ning, Loo Brandon, Sritharan Hari, Rye Eleanor, Everett Kay, Jabbour Andrew, Hayward Christopher, Kapur Navin K, Muller David W M, Adji Audrey I. The effect of increased vascular afterload measures on flow rate and survival in severe aortic stenosis.. European heart journal. Cardiovascular Imaging. 2025. DOI: 10.1093/ehjci/jeae331.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.