MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001556

Медицинская библиотека · Journal of cataract and refractive surgery · 2025

Prediction of vaults in eyes with vertical implantable collamer lens implantation.

Shimada Ryuichi, Katagiri Satoshi, Horiguchi Hiroshi, Nakano Tadashi, Kitazawa Yoshihiro

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To design formulas for predicting postoperative vaults in vertical implantable collamer lens (ICL) implantation and to achieve more precise predictions using machine learning models.

DESIGN

Retrospective, observational study.

SETTING

Eye Clinic Tokyo.

METHODS

We retrospectively reviewed the medical records of 720 eyes in 408 patients who underwent vertical ICL implantation. The data included age, sex, refractions, anterior segment biometric data, and surgical records. We designed 3 formulas (named V1 to V3 formulas) using multiple linear regression analysis and tested 4 machine learning models.

RESULTS

Predicted vaults by V1 to V3 formulas were 444.17 ± 93.83 μm, 444.08 ± 98.64 μm, and 444.27 ± 108.81 μm, with a mean absolute error of 127.97 ± 107.92 μm, 126.41 ± 105.86 μm, and 122.90 ± 103.00 μm, respectively. There were no significant differences in error among the V1 to V3 formulas, despite the fact that the V1 and V2 formulas referred to limited parameters (3 and 4, respectively) and the V3 formula referred to all 12 parameters. 2 of 4 machine learning models-Extreme Gradient Boosting and Random Forest Regressor-showed better performance in predicted vaults: 444.52 ± 120.51 μm and 446.00 ± 102.55 μm, and mean absolute error: 118.31 ± 100.55 μm and 118.63 ± 99.34 μm, respectively.

CONCLUSIONS

This is the first study to design V1 to V3 formulas for vertical ICL implantation. The V1 and V2 formulas exhibited good performance despite the limited parameters. In addition, 2 of the 4 machine learning models predicted more precise results.

Для цитирования: Shimada Ryuichi, Katagiri Satoshi, Horiguchi Hiroshi, Nakano Tadashi, Kitazawa Yoshihiro. Prediction of vaults in eyes with vertical implantable collamer lens implantation.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001556.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.