MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001555

Медицинская библиотека · Journal of cataract and refractive surgery · 2025

Using first-eye early vault to determine implantable collamer lens size for the second eye: retrospective analysis of bilateral phakic intraocular lens implantation.

Li Honglei, Liu Dongle, Zhang Jinyan, Dai Yunhai, Wu Xiaoming

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the role of first-eye vault after the implantation of implantable collamer lens (ICL) V4c in selecting ICL size for the second eye and analyze the changing characteristics of the vault.

SETTING

Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China.

DESIGN

Retrospective case series.

METHODS

In this retrospective study, 509 patients (1018 eyes) receiving bilateral ICL V4c implants were evaluated. The surgical management method was as follows: The vault was measured at 2 hours after the first-eye surgery, and we selected ICL size for the second eye based on the vault of the first eye. The bilateral vault was measured and evaluated between different periods of follow-up.

RESULTS

The rate of ICL realignment or exchange due to abnormal vault was 1.47% (15/1018), with the second eye showing a significantly lower incidence (0.39%) compared with the first eye (2.55%) ( P < .01). Patients were categorized into 4 groups based on the vault value obtained at 2 hours postoperatively (baseline). There was significant difference in the value of vault decrease among the 4 groups at 1-day, 1-week, 1-month, and 3-month follow-ups (all P < .01). There was a significant positive correlation between the decrease in the vault and the baseline vault (all P < .01).

CONCLUSIONS

Selecting the ICL size for the second eye based on the first eye's vault measurement 2 hours postoperatively can effectively minimize the need for further surgeries. Notably, eyes with a higher initial vault experienced a more pronounced decrease.

Для цитирования: Li Honglei, Liu Dongle, Zhang Jinyan, Dai Yunhai, Wu Xiaoming. Using first-eye early vault to determine implantable collamer lens size for the second eye: retrospective analysis of bilateral phakic intraocular lens implantation.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001555.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.