DOI 10.1016/s0360-3016(03)00586-8
Assessment of focal liver reaction by multiphasic CT after stereotactic single-dose radiotherapy of liver tumors.
Аннотация
PURPOSE: To characterize and quantitatively assess focal radiation reactions in the liver after stereotactic single-dose radiotherapy for liver malignancies.
METHODS AND MATERIALS: A total of 131 multiphasic CT scans were performed in 36 patients before and after stereotactic radiotherapy for liver tumors. The examination protocol included a nonenhanced scan and contrast-enhanced scans at different times after contrast injection. The volume of the reaction was determined in each scan and the threshold dose calculated using the dose-volume histogram of the treatment plan.
RESULTS
Every patient showed a focal radiation reaction on at least one follow-up examination. In 74% of the posttherapeutic scans, a sharply demarcated hypodense area surrounded the treated tumor in the nonenhanced scans. The reaction occurred at a median of 1.8 months (range 1.2-4.6) after radiotherapy. The median threshold dose was 13.7 Gy (range 8.9-19.2). The threshold dose strongly correlated with the time of detection after therapy (r = 0.7). Radiologically, three reaction types were found on the enhanced scans: type 1, portal-venous phase: hypodense and late phase: isodense; type 2, portal-venous phase: hypodense and late phase: hyperdense; and type 3, portal-venous phase: isodense/hyperdense and late phase: hyperdense. Type 1 or 2 reactions were observed significantly earlier than type 3 (p <0.05). The median threshold dose for type 1 or 2 reactions was significantly lower than for type 3 (p <0.05). The reaction volume decreased with longer follow-up (2-4 months: median 40% of initial volume). The reaction types shifted with follow-up: 58% were of type 1 at the initial manifestation and 58% were of type 3 at the next examination thereafter.
CONCLUSION
A focal radiation reaction occurs after stereotactic single-dose therapy in the liver. The volume of the reaction decreases and changes its radiologic appearance during follow-up. This reaction has to be differentiated from recurrent tumor.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.