DOI 10.1002/jmri.29225

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2024

MRI-Based Kinetic Heterogeneity Evaluation in the Accurate Access of Axillary Lymph Node Status in Breast Cancer Using a Hybrid CNN-RNN Model.

Guo Yi-Jun, Yin Rui, Zhang Qian, Han Jun-Qi, Dou Zhao-Xiang, Wang Peng-Bo, Lu Hong, Liu Pei-Fang, Chen Jing-Jing, Ma Wen-Juan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Accurate evaluation of the axillary lymph node (ALN) status is needed for determining the treatment protocol for breast cancer (BC). The value of magnetic resonance imaging (MRI)-based tumor heterogeneity in assessing ALN metastasis in BC is unclear.

PURPOSE: To assess the value of deep learning (DL)-derived kinetic heterogeneity parameters based on BC dynamic contrast-enhanced (DCE)-MRI to infer the ALN status.

STUDY TYPE: Retrospective.

SUBJECTS: 1256/539/153/115 patients in the training cohort, internal validation cohort, and external validation cohorts I and II, respectively.

FIELD STRENGTH/SEQUENCE: 1.5 T/3.0 T, non-contrast T1-weighted spin-echo sequence imaging (T1WI), DCE-T1WI, and diffusion-weighted imaging.

ASSESSMENT: Clinical pathological and MRI semantic features were obtained by reviewing histopathology and MRI reports. The segmentation of the tumor lesion on the first phase of T1WI DCE-MRI images was applied to other phases after registration. A DL architecture termed convolutional recurrent neural network (ConvRNN) was developed to generate the KHimage (kinetic heterogeneity of DCE-MRI image) score that indicated the ALN status in patients with BC. The model was trained and optimized on training and internal validation cohorts, tested on two external validation cohorts. We compared ConvRNN model with other 10 models and the subgroup analyses of tumor size, magnetic field strength, and molecular subtype were also evaluated.

STATISTICAL TESTS: Chi-squared, Fisher's exact, Student's t, Mann-Whitney U tests, and receiver operating characteristics (ROC) analysis were performed. P < 0.05 was considered significant.

RESULTS

The ConvRNN model achieved area under the curve (AUC) of 0.802 in the internal validation cohort and 0.785-0.806 in the external validation cohorts. The ConvRNN model could well evaluate the ALN status of the four molecular subtypes (AUC = 0.685-0.868). The patients with larger tumor sizes (>5 cm) were more susceptible to ALN metastasis with KHimage scores of 0.527-0.827.

DATA

CONCLUSION

A ConvRNN model outperformed traditional models for determining the ALN status in patients with BC.

LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

Для цитирования: Guo Yi-Jun, Yin Rui, Zhang Qian, Han Jun-Qi, Dou Zhao-Xiang, Wang Peng-Bo, Lu Hong, Liu Pei-Fang, Chen Jing-Jing, Ma Wen-Juan. MRI-Based Kinetic Heterogeneity Evaluation in the Accurate Access of Axillary Lymph Node Status in Breast Cancer Using a Hybrid CNN-RNN Model.. Journal of magnetic resonance imaging : JMRI. 2024. DOI: 10.1002/jmri.29225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.