Медицинская библиотека · The American surgeon · 2023

The Efficacy of Axillary Reverse Mapping for the Prevention of Lymphedema.

Ruffino Amanda E, Madera Joshua D, Dearborn Makayla M, Frank Katie, Oxenberg Jacqueline C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Lymphedema (LE) is the most notable complication of axillary surgery. The axillary reverse mapping (ARM) technique was created to decrease LE. This study aims to evaluate a single surgeon's experience with ARM in patients undergoing sentinel lymph node biopsy (SLNB) or axillary lymph node dissection (ALND) for breast cancer.

METHODS

We retrospectively analyzed patients who underwent SLNB or ALND. Tumor characteristics and treatments received were evaluated. Surgical intervention and use of ARM were compared to assess LE rates. A subgroup analysis was also performed of patients who underwent NAC.

RESULTS

LE was initially reported in 7.1% (n = 10) of patients; 3.3% (n = 4) with SLNB and 35% (n = 6) with ALND. At initial follow-up, LE was reported 16.4% more often in patients who underwent ALND with no ARM, and 38.8% more often in patients who underwent ALND plus ARM. An increased risk of LE was found in patients treated with ALND (OR = 16.0, P < .001). All patients who underwent ARM were 12.75% more likely to develop LE if they received NAC (P < .05). Patients in the ALND group who also received NAC were more likely to undergo ARM as compared with patients in the SLNB group (P < .01).

DISCUSSION: Our study showed that ARM failed to decrease the incidence of LE. Until better surgical outcomes are shown for the prevention of LE using ARM, other approaches should be utilized. However, larger prospective studies are needed to evaluate ARM.

Для цитирования: Ruffino Amanda E, Madera Joshua D, Dearborn Makayla M, Frank Katie, Oxenberg Jacqueline C. The Efficacy of Axillary Reverse Mapping for the Prevention of Lymphedema.. The American surgeon. 2023. DOI: 10.1177/00031348231198103.