Fluctuation in straylight measurements during the visual recovery phase after small incision lenticule extraction.
Аннотация
PURPOSE: To investigate the postoperative straylight changes during the visual recovery phase after small incision lenticule extraction (SMILE) and their association.
METHODS
Seventy consecutive eyes from 37 patients with a mean age of 30.92 ± 7.26 years and a mean preoperative spherical equivalent of -5.24 ± 1.90 dioptres undergoing myopic or myopic astigmatism SMILE correction were included in this prospective study. Patients were followed up at days 1, 3, 7, 14, 21 and 28 after standard SMILE. Straylight was measured using the C-Quant straylight meter (Oculus GmbH, Germany) preoperatively and at each postoperative visit.
RESULTS
Preoperatively, the mean straylight measurement was 1.16 ± 0.16. After SMILE, the mean straylight values were 1.12 ± 0.14 and 1.13 ± 0.13 at days 7 and 14, which were significantly reduced compared to preoperative values (p ≤ 0.028). Straylight returned to baseline by week 3 (p = 0.160) and remained stable onwards (p = 0.651). A lower ablation ratio was associated with less straylight level at days 1, 3, 14 and 21 (p ≤ 0.0497) in the multivariable regression model. Likewise, better visual acuity was associated with lower straylight at days 7, 14 and 28 postoperatively (p ≤ 0.038). A small proportion of eyes (range: 0-12.86%) had ≥0.30 log(s) increase in postoperative straylight within the first month after SMILE.
CONCLUSIONS
SMILE induced a temporary decrease in straylight. It gradually returned to the preoperative level, which could be related to a number of dynamic processes during corneal healing. In the small proportion of patients with an increase in straylight postoperatively, this can affect their visual recovery during the early postoperative period.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.