PURPOSE: To determine surgical parameters for arcuate keratotomy by simulating the intervention with a patient-specific model.

SETTING

University Eye Clinic Salzburg, Paracelsus Medical University, Austria, and Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland.

DESIGN

Computational modeling study.

METHODS

A new approach to plan arcuate keratotomy based on personalized finite element simulations was developed. Using this numeric tool, an optimization algorithm was implemented to determine the incision parameters that best met the surgeon's requirements while preserving the orientation of the astigmatism. Virtual surgeries were performed on patients to compare the performance of the simulation-based approach with results based on the Lindstrom and Donnenfeld nomograms and with intrastromal interventions.

RESULTS

Retrospective data on 28 patients showed that personalized simulation reproduced the surgically induced change in astigmatism (Pearson correlation = 0.8). Patient-specific simulation was used to examine strategies for arcuate interventions on 621 corneal topographies. The Lindstrom nomogram resulted in low postoperative astigmatism (mean 0.03 diopter [D] ± 0.3 [SD]) but frequent overcorrections (20%). The Donnenfeld nomogram and intrastromal incisions resulted in a small amount of overcorrection (1.5%) but a wider spread in astigmatism (mean 0.63 ± 0.35 D and 0.48 ± 0.50 D, respectively). In contrast, the new numeric parameter optimization approach led to postoperative astigmatism values (mean 0.40 ± 0.08 D, 0.20 ± 0.08 D, and 0.04 ± 0.13 D) that closely matched the target astigmatism (0.40 D, 0.20 D, and 0.00 D), respectively, while keeping the number of overcorrections low (<1.5%).

CONCLUSION

Using numeric modeling to optimize surgical parameters for arcuate keratotomy led to more reliable postoperative astigmatism, limiting the risk for overcorrection.

Для цитирования: Truffer Oskar, Abler Daniel, Pajic Bojan, Grabner Günther, Kraker Hannes, Büchler Philippe. Optimization of surgical parameters based on patient-specific models: Application to arcuate keratotomy.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2019.02.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.