DOI 10.1097/ico.0000000000002052

Медицинская библиотека · Cornea · 2020

Comparison of Corneal Power and Corneal Astigmatism of Different Diameter Zones Centered on the Pupil and Corneal Apex Using Scheimpflug Tomography.

Dong Jing, Zhang Yaqin, Zhou Jing, Zhang Suhua, Sun Bin, Tang Maolong, Wang Xiaogang

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Using Scheimpflug tomography to investigate the difference in corneal power and corneal astigmatism between 3- and 4-mm diameter zones centered on the pupil and corneal apex.

METHODS

A total of 90 eyes were included in this study. Axial keratometry, total refractive power, and true net power centered on the pupil and corneal apex in 3- and 4-mm diameter zones were assessed. The paired sample t test and independent sample t test were used for data comparison.

RESULTS

For corneal power and corneal astigmatism for the 3- and 4-mm diameter zones, the flat K values of axial keratometry, total refractive power, and true net power centered on the pupil (3-mm: 43.99 ± 1.69 D, 43.12 ± 1.71 D, 42.53 ± 1.67 D; 4-mm: 44.04 ± 1.67 D, 43.38 ± 1.71 D, 42.61 ± 1.65 D) were significantly higher than those centered on the apex (3-mm: 43.93 ± 1.69 D, 43.05 ± 1.71 D, 42.46 ± 1.67 D; 4-mm: 44.01 ± 1.67 D, 43.34 ± 1.69 D, 42.58 ± 1.65 D; all P < 0.02). However, the steep K and astigmatism magnitude values centered on the pupil (3-mm: 45.71 ± 1.73 D, 45.01 ± 1.73 D, 44.38 ± 1.69 D; 1.72 ± 0.83 D, 1.89 ± 0.86 D, 1.85 ± 0.84 D; 4-mm: 45.78 ± 1.73 D, 45.28 ± 1.74 D, 44.45 ± 1.68 D; 1.73 ± 0.84 D, 1.90 ± 0.85 D, 1.84 ± 0.85 D) were lower than those centered on the apex (3-mm: 45.81 ± 1.74 D, 45.10 ± 1.72 D, 44.50 ± 1.70 D; 1.88 ± 0.90 D, 2.05 ± 0.90 D, 2.04 ± 0.90 D; 4-mm: 45.85 ± 1.73 D, 45.34 ± 1.73 D, 44.51 ± 1.69 D; 1.83 ± 0.88 D, 2.00 ± 0.90 D, 1.93 ± 0.86 D; all P < 0.01). Compared with the 3-mm diameter zone, the corresponding 4-mm diameter zone showed higher corneal power centered on both pupil and corneal apex.

CONCLUSIONS

The difference in corneal power and corneal astigmatism, measured at 3 and 4 mm, centered on the pupil and the corneal apex should be noted in corneal refractive surgery and toric intraocular lens calculation.

Для цитирования: Dong Jing, Zhang Yaqin, Zhou Jing, Zhang Suhua, Sun Bin, Tang Maolong, Wang Xiaogang. Comparison of Corneal Power and Corneal Astigmatism of Different Diameter Zones Centered on the Pupil and Corneal Apex Using Scheimpflug Tomography.. Cornea. 2020. DOI: 10.1097/ico.0000000000002052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.