MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/02713683.2019.1638943

Медицинская библиотека · Current eye research · 2019

Ocular Cyclorotation and Corneal Axial Misalignment in Femtosecond Laser-Assisted Cataract Surgery.

Xiang Wu, Chen Wan, Liu Rongjiao, Chen Hui, Yang Chunyan, Zhong Liting, Zhang Shaochong, Chen Weirong

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Purpose: To explore ocular cyclorotation and the source of corneal axial misalignment during femtosecond laser-assisted cataract surgery (FLACS).

Methods

Forty-five sequential patients (50 eyes) who had undergone FLACS (LenSx Laser System, Alcon Inc) were recruited. We took screenshots from videos of FLACS to analyze ocular cyclorotation and the real angle between primary incision and secondary incision (RAPS). In addition, crystalline lens tilt and theoretic angle between the primary and secondary incisions (TAPS) was also calculated.

Results

The mean absolute value of ocular cyclorotation was 8.03 ± 4.48 degrees (0-19.1 degrees). The crystalline lens tilt was 3.30 ± 1.44 degrees (0.93-6.44 degrees). And the mean preoperative uncorrected visual acuity was 0.89 ± 0.50 LogMAR units. Pearson bivariate correlation analysis showed significant positive correlation between ocular cyclorotation with crystalline lens tilt (r = 0.37, p = .008), and ocular cyclorotation negatively correlated with axial length (r = -0.29, p = .038). In addition, the TAPS was 89.78 ± 1.45 degrees, and the RAPS was 85.68 ± 2.04 degrees. The angle error was 4.11 ± 1.28 degrees (p<0.001).

Conclusions

Ocular cyclorotation commonly occurred during FLACS. In addition, increased axial length was associated with less ocular cyclorotation and increased crystalline lens tilt was related to more ocular cyclorotation. Importantly, machinery systemic errors during corneal astigmatism correction by arcuate incision in FLACS should be taken into consideration.

Для цитирования: Xiang Wu, Chen Wan, Liu Rongjiao, Chen Hui, Yang Chunyan, Zhong Liting, Zhang Shaochong, Chen Weirong. Ocular Cyclorotation and Corneal Axial Misalignment in Femtosecond Laser-Assisted Cataract Surgery.. Current eye research. 2019. DOI: 10.1080/02713683.2019.1638943.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.