Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Igarashi Akihito, Shimizu Kimiya, Kato Sayaka, Kamiya Kazutaka
Аннотация
PURPOSE: To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT).
SETTING: Sanno Hospital, Tokyo, Japan.
DESIGN: Retrospective case series.
METHODS: Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept-source AS-OCT CASIA2 system.
RESULTS: The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), -6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance (r = 0.27, P = .08).
CONCLUSION: The ATA measurements had higher reproducibility than the WTW measurements on AS-OCT, making it is a more important predictor of postoperative vault.
SETTING: Sanno Hospital, Tokyo, Japan.
DESIGN: Retrospective case series.
METHODS: Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept-source AS-OCT CASIA2 system.
RESULTS: The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), -6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance (r = 0.27, P = .08).
CONCLUSION: The ATA measurements had higher reproducibility than the WTW measurements on AS-OCT, making it is a more important predictor of postoperative vault.